Jump to navigation Jump to search
Line 27: Line 27:
The methods and results described in the present Application challenge are mainly adopted from Janke et al. (2019) (experimental part) and Koullapis et al. (2018) (numerical part), reporting on work carried out in COST Action MP1404 SimInhale ‘Simulation and pharmaceutical technologies for advanced patient-tailored inhaled medicines’. http://www.siminhale-cost.eu.
The methods and results described in the present Application challenge are mainly adopted from Janke et al. (2019) (experimental part) and Koullapis et al. (2018) (numerical part), reporting on work carried out in COST Action MP1404 SimInhale ‘Simulation and pharmaceutical technologies for advanced patient-tailored inhaled medicines’. http://www.siminhale-cost.eu.


[[File:PIV setup.png|thumb|CAD rendering of the mounting construction for the transparent silicone model.]]
[[File:PIV setup.png| center |CAD rendering of the mounting construction for the transparent silicone model.]]


<br/>
<br/>
Line 37: Line 37:
|authors=P. Koullapis<sup>a</sup>, J. Muela<sup>b</sup>, O. Lehmkuhl<sup>c</sup>, F. Lizal<sup>d</sup>, J. Jedelsky<sup>d</sup>, M. Jicha<sup>d</sup>, T. Janke<sup>e</sup>, K. Bauer<sup>e</sup>, M. Sommerfeld<sup>f</sup>, S. C. Kassinos<sup>a</sup>
|authors=P. Koullapis<sup>a</sup>, J. Muela<sup>b</sup>, O. Lehmkuhl<sup>c</sup>, F. Lizal<sup>d</sup>, J. Jedelsky<sup>d</sup>, M. Jicha<sup>d</sup>, T. Janke<sup>e</sup>, K. Bauer<sup>e</sup>, M. Sommerfeld<sup>f</sup>, S. C. Kassinos<sup>a</sup>
|organisation=<br><sup>a</sup>Department of Mechanical and Manufacturing Engineering, University of Cyprus, Nicosia, Cyprus<br>
|organisation=<br><sup>a</sup>Department of Mechanical and Manufacturing Engineering, University of Cyprus, Nicosia, Cyprus<br>
organisation=<br><sup>b</sup>Heat and Mass Transfer Technological Centre, Universitat Politècnica de Catalunya, Terrassa, Spain<br>
<sup>b</sup>Heat and Mass Transfer Technological Centre, Universitat Politècnica de Catalunya, Terrassa, Spain<br>
organisation=<br><sup>c</sup>Barcelona Supercomputing center, Barcelona, Spain <br>
<sup>c</sup>Barcelona Supercomputing center, Barcelona, Spain <br>
organisation=<br><sup>d</sup>Faculty of Mechanical Engineering, Brno University of Technology, Brno, Czech Republic<br>
<sup>d</sup>Faculty of Mechanical Engineering, Brno University of Technology, Brno, Czech Republic<br>
organisation=<br><sup>e</sup>Institute of Mechanics and Fluid Dynamics, TU Bergakademie Freiberg, Freiberg, Germany<br>
<sup>e</sup>Institute of Mechanics and Fluid Dynamics, TU Bergakademie Freiberg, Freiberg, Germany<br>
organisation=<br><sup>f</sup>Institute Process Engineering, Otto von Guericke University, Halle (Saale), Germany <br>
<sup>f</sup>Institute Process Engineering, Otto von Guericke University, Halle (Saale), Germany <br>
}}
}}
{{ACHeader
{{ACHeader

Revision as of 20:20, 15 May 2020

Front Page

Description

Test Data

CFD Simulations

Evaluation

Best Practice Advice

Airflow in the human upper airways

Application Area 7: Biomedical Flows

Application Challenge AC7-02

Abstract


Knowledge of deposition characteristics in the human airways is important when assessing the impact of inhaled aerosols, which can be either atmospheric pollutants or aerosols intended for therapeutic purposes. Not only the total deposition, but also local depositions within individual parts of the lung are of interest. Aerosol transport is determined by the airflow characteristics in the human airways. In particular, aerosol deposition in the upper airways is mainly attributed to inertial impaction which in turn is associated to forces exerted on the particles by the flow. In addition, the transition to turbulent flow causes deposition of particles due to turbulent dispersion. The application of computer models that are based on computational fluid dynamics for the prediction of airflow and deposition in the human airways has become very common nowadays. Despite their limitations, which are mainly associated to their high computational cost, CFD models offer significant advantages over in vitro / in vivo experiments. However, prior to their use CFD models need to be properly validated. This is the objective of the current application challenge. Specifically, flow measurements using Particle Image Velocimetry (PIV) have been conducted in a human-based model of the upper airway during steady-state inhalation at a flow rate of 60 L/min. The flow conditions at these flowrates are in the transitional to turbulent regime. CFD simulations were carried out in the same geometry and under the same ventilation conditions. Large Eddy Simulations using three different approaches and Reynolds-Averaged Navier-Stokes simulations were carried out.

The present AC is associated to AC7-01: “Aerosol deposition in the human upper airways” of Application Area 7: Biomedical Flows, which presents experimental and numerical results for deposition in the same geometry. The methods and results described in the present Application challenge are mainly adopted from Janke et al. (2019) (experimental part) and Koullapis et al. (2018) (numerical part), reporting on work carried out in COST Action MP1404 SimInhale ‘Simulation and pharmaceutical technologies for advanced patient-tailored inhaled medicines’. http://www.siminhale-cost.eu.

CAD rendering of the mounting construction for the transparent silicone model.



Contributed by: P. Koullapisa, J. Muelab, O. Lehmkuhlc, F. Lizald, J. Jedelskyd, M. Jichad, T. Jankee, K. Bauere, M. Sommerfeldf, S. C. Kassinosa — 
aDepartment of Mechanical and Manufacturing Engineering, University of Cyprus, Nicosia, Cyprus
bHeat and Mass Transfer Technological Centre, Universitat Politècnica de Catalunya, Terrassa, Spain
cBarcelona Supercomputing center, Barcelona, Spain
dFaculty of Mechanical Engineering, Brno University of Technology, Brno, Czech Republic
eInstitute of Mechanics and Fluid Dynamics, TU Bergakademie Freiberg, Freiberg, Germany
fInstitute Process Engineering, Otto von Guericke University, Halle (Saale), Germany