Mixing ventilation flow in an enclosure driven by a transitional wall jet
Confined Flows
Underlying Flow Regime 4-20
References
- Awbi HB, 2003. Ventilation of buildings. Spon Press, London.
- Awbi HB, 2007. Ventilation systems: design and performance. London: Taylor & Francis.
- Bajura RA, Catalano MR, 1975. Transition in a two-dimensional plane wall jet. J Fluid Mech 70:773-799.
- Bell JH, Mehta RD, 1988. Contraction design for small low-speed wind tunnels. NASA CR-177488; 1988.
- Brassard D, Ferchichi M, 2005. Transformation of a polynomial for a contraction wall profile. J Fluids Eng 127:183-85.
- Chang KC, Hsieh, WD, Chen, CS, 1995. A modified low-Reynolds-number turbulence model applicable to recirculating flow in pipe expansion, Journal of Fluids Engineering, 117, 417–423.
- Casey M, Wintergerste T (Eds). Best Practice Guidelines, ERCOFTAC Special Interest Group on Quality and Trust in Industrial CFD, ERCOFTAC, Triomflaan 43, B-1160, Brussels; 2000.
- Chen Q, 1995. Comparison of different k-ε models for indoor airflow computations. Numer Heat Tr B-Fund 28:353-69.
- Chen Q, 1996. Prediction of room air motion by Reynolds-stress models. Build Environ 31:233-44.
- Chen Q, 2009. Ventilation performance prediction for buildings: A method overview and recent applications. Build Environ 44:848-858.
- Coleman HW, Steel WG, 1999. Experimentation and uncertainty analysis for engineers. Wiley and Sons, New York, USA.
- Davidson L, Nielsen PV, Topp C, 2000. Low Reynolds number effects in ventilated rooms: a numerical study. Proc. of Roomvent 2000, Oxford: 307-312.
- Defraeye T, 2006. Design of a vertical wind tunnel for heat and mass transfer coefficients. M.Sc. thesis. Laboratory of Building Physics, Department of Civil Engineering, K.U.Leuven.
- Durbin PA, 1995. Separated flow computations with the k-ε-v2 Model. AIAA Journal. 33(4). 659–664. 1995.
- Etheridge DW, Sandberg M, 1996. Building Ventilation: Theory and Measurement. London: Wiley.
- Fluent Inc. 2006. Fluent 6.3 user’s guide, Lebanon.
- Glauert P, 1956. The wall jet. J Fluid Mech 1:625-643.
- Gogineni S, Shih C, 1997. Experimental investigation of the unsteady structure of a transitional plane wall jet. Exp Fluids 23:121-129.
- Jiang Y, Chen Q, 2002. Effect of fluctuating wind direction on cross natural ventilation in buildings from large eddy simulation. Build Environ 37(4):379-86.
- Heiselberg P, Li Y, Andersen A, Bjerre M, Chen Z, 2004. Experimental and CFD evidence of multiple solutions in a naturally ventilated building. Indoor Air 14(1):43–54.
- Hsiao FB, Sheu SS, 1994. Double row vortical structures in the near field region of a plane wall jet. Exp Fluids 17:291-301.
- Hu C-H, Ohba M, Yoshie R, 2008. CFD modelling of unsteady cross ventilation flows using LES. J Wind Eng Ind Aerodyn 96(10-11):1692-1706.
- Keane RD, Adrian RJ, 1990. Optimization of particle image velocimeters. Part I: Double pulsed systems. Meas Sci Technol 1, 1202-1215.
- Langtry RB, Menter FR, 2009. Correlation-based transition modeling for unstructured parallelized computational fluid dynamics codes. AIAA Journal 47(12), 2894–2906.
- Launder BE, Rodi W, 1981. The turbulent wall jet. Prog Aerospace Sci 19:81-128.
- Lichter S, Flór JB, van Heijst GJF, 1992. Modelling the separation and eddy formation of coastal currents in a stratified tank. Exp Fluids 13:11-16.
- Li Y, Nielsen PV, 2011. CFD and ventilation research. Indoor Air 21:442-53.
- Menter FR, 1994. Two-equation eddy-viscosity turbulence models for engineering applications. AIAA Journal, 32, 1598–1605.
- Menter FR, Langtry R, Völker S, 2006. Flow Turbulence Combust 77: 277-303.
- Menter FR, Smirnov PE, Liu T, Avancha R, 2015. A one-equation local correlation-based transition model. Flow Turbulence Combust 95,4 583-619.
- Nielsen PV, 1974. Flow in air conditioned rooms, PhD Thesis, Technical University of Denmark, Copenhagen.
- Nielsen PV, 1990. Specification of a two-dimensional test case. International Energy Agency, Energy Conservation in Buildings and Community Systems, Annex 20: Airflow Pattern within Buildings.
- Nielsen PV, 1998. The selection of turbulence models for prediction of room airflow. ASHRAE T 104(1B):1119-27.
- Nielsen PV, Filholm C, Topp C, Davidson L, 2000. Model experiments with low Reynolds number effects in a ventilated room. Proc. of Roomvent 2000), Oxford:185-190.
- Norton T, Grant J, Fallon R, Sun D-W, 2009. Assessing the ventilation effectiveness of naturally ventilated livestock buildings under wind dominated conditions using computational fluid dynamics. Biosystems Eng 2103(1):78-99.
- Prasad AK, 2000. Particle image velocimetry. Curr Sci;79:51-60.
- Ramponi R, Blocken B, 2012. CFD simulation of cross-ventilation for a generic isolated building: impact of computational parameters. Build Environ, 53, 34-48.
- Sørensen DN, Nielsen PV, 2003. Quality control of computational fluid dynamics in indoor environments. Indoor Air 13:2–17.
- Topp C, Nielsen PV, Davidson L, 2000. Room airflows with low Reynolds number effects. Proc. of Roomvent 2000), Oxford:541-546.
- van Hooff T, Blocken B, 2010. Coupled urban wind flow and indoor natural ventilation modelling on a high-resolution grid: A case study for the Amsterdam ArenA stadium. Environ Modell Softw, 25(1), 51-65.
- van Hooff T, Blocken B, 2010. On the effect of wind direction and urban surrounding on natural ventilation of a large semi-enclosed stadium. Comput Fluids 39: 1146-55.
- van Hooff T, Blocken B, Defraeye T, Carmeliet J, van Heijst GJF, 2012a. PIV measurements of a plane wall jet in a confined space at transitional slot Reynolds numbers. Exp Fluids, 53(2), 499-517.
- van Hooff T, Blocken B, Defraeye T, Carmeliet J, van Heijst GJF, 2012b. PIV measurements and analysis of transitional flow in a reduced-scale model: ventilation by a free plane jet with Coanda effect. Build Environ, 56, 301-313.
- van Hooff T, Blocken B, Aanen L, Bronsema B, 2012c. Numerical analysis of the performance of a venturi-shaped roof for natural ventilation: influence of building width. J Wind Eng Ind Aerodyn, 104-106, 419-427.
- van Hooff T, Blocken B, van Heijst GJF, 2013. On the suitability of steady RANS CFD for forced mixing ventilation at transitional slot Reynolds numbers. Indoor Air 23, 236-249.
- van Hooff T, Blocken B, Gousseau P, van Heijst GJF, 2014. Counter-gradient diffusion in a slot-ventilated enclosure assessed by LES and RANS. Comput Fluids 96, 63-75.
- van Hooff T, Blocken B, 2017. Low-Reynolds number mixing ventilation flows: impact of physical and numerical diffusion on flow and dispersion. Build Simul 10(4): 589-606.
- Verhoff A, 1963. The two-dimensional turbulent wall jet with and without an external stream. Report 626, Princeton University, New Jersey, USA.
- Wang M, Chen Q, 2009. Assessment of various turbulence models for transitional flows in enclosed environment. HVAC&R Res, 15:1099-1119.
- Wang M, Chen Q, 2010. On a hybrid RANS/LES approach for indoor airflow modelling. HVAC&R Res, 16:731-747.
- Wilcox DC, 1998. Turbulence Modeling for CFD. DCW Industries, Inc., La Canada, California.
- Wright NG, Hargreaves DM, 2006. Unsteady CFD simulations for natural ventilation. Int J Vent 5(1):13-20.
- Yakhot V, Orszag SA, Thangam S, Gatski TB, Speziale CG, 1992. Development of turbulence models for shear flows by a double expansion technique, Phys Fluids A, 4, 1510-1520.
- Zhang G, Morsing S, Bjerg B Svidt K, Strøm JS, 2000. Test room for validation of airflow patterns estimated by computational fluid dynamics. J Agric Eng Res 76:141-48.
Contributed by: T. van Hooff(*), B. Blocken(*), G.J.F. van Heijst(**) — (*)Dept. of Civil Engineering, KU Leuven, Belgium and Dept. of the Built Environment, Eindhoven University of Technology, the Netherlands.
(**)Dept. of Applied Physics, Eindhoven University of Technology, the Netherlands
© copyright ERCOFTAC 2024