Best Practice Advice AC2-09

From KBwiki
Jump to navigation Jump to search


Front Page

Description

Test Data

CFD Simulations

Evaluation

Best Practice Advice

SANDIA Flame D

Application Challenge AC2-09   © copyright ERCOFTAC 2024

Best Practice Advice

Key Fluid Physics

The non-premixed Sandia D flame is an example of a flame in the flamelet regime in which the Kolmogorov scale is significantly larger than the scales characteristic for the combustion process. In this not demanding test case the models based on flamelet assumption should lead to good agreement with experimental data as was shown in the Evaluation section, especially in the region of developed flame. However, more discrepancies were observed in the near field were only mixing of fuel and oxidizer is considered.

Application Uncertainties

The flow field in the near field is certainly influenced by inlet conditions. The mean velocity profile and fluctuating component were chosen according to the experimental data. However, in the unsteady LES calculations the fluctuations were simulated by white noise. This means that the fluctuations characteristic for developed turbulent flow were not reproduced at the inlet and this could influence the mixing features in the near field. It is well known that white noise provides a fluctuating signal with a very short time scale which is then smoothed at a short distance from the inlet plane. However, it seems that due to very low inlet turbulence level the further results in the flame region are only weakly influenced by these near field results as both models analyzed led to reasonable results.

Computational Domain and Boundary Conditions

Discretisation and Grid Resolution

Physical Modelling

Recommendations for Future Work




Contributed by: Andrzej Boguslawski — Technical University of Częstochowa