Jump to navigation Jump to search
Line 17: Line 17:
software for the Conditional Moment Closure model used in  calculations
software for the Conditional Moment Closure model used in  calculations
was developed by Professor E. Mastorakos at  Cambridge  University  and
was developed by Professor E. Mastorakos at  Cambridge  University  and
implemented in the BOFFIN-LES code by the  team  of  the  Institute  of
implemented in the BOFFIN-LES code by the  team  of  the  Institute  of Thermal Machinery.
Thermal Machinery.


Sandia Flame D is a  widely  used  test  case  for  the  validation  of
    Sandia Flame D is a  widely  used  test  case  for  the  validation  of
numerical models of non-premixed  combustion.  This  flame  is  of  the
    numerical models of non-premixed  combustion.  This  flame  is  of  the
flamelet regime type in which  a  scale  separation  appears  i.e.  the
    flamelet regime type in which  a  scale  separation  appears  i.e.  the
smallest scales of the  turbulent  flow,  the  Kolmogorov  scales,  are
    smallest scales of the  turbulent  flow,  the  Kolmogorov  scales,  are
significantly larger than the scales characteristic  for  the  reaction
    significantly larger than the scales characteristic  for  the  reaction
zone.  Such  a  flame  facilitates  the  study  of  models  of
    zone.  Such  a  flame  facilitates  the  study  of  models  of
turbulence/chemistry interaction, allowing to separate the influence of
    turbulence/chemistry interaction, allowing to separate the influence of
turbulence  and  turbulence/chemistry  interaction  models  from  the
    turbulence  and  turbulence/chemistry  interaction  models  from  the
influence of chemical kinetics models applied. Non-premixed  combustion
    influence of chemical kinetics models applied. Non-premixed  combustion
is limited by turbulent mixing and dominated by large scale structures.
    is limited by turbulent mixing and dominated by large scale structures.
The quality of unsteady flow dynamics predictions seems to  be  crucial
    The quality of unsteady flow dynamics predictions seems to  be  crucial
for the quality of the overall combustion process. Hence,  within  this
    for the quality of the overall combustion process. Hence,  within  this
document attention is restricted to LES calculations and  neither  RANS
    document attention is restricted to LES calculations and  neither  RANS
nor URANS predictions are included or analyzed.
    nor URANS predictions are included or analyzed.


     To evaluate the sensitivity of the  subgrid-scale-modeling  quality  on
     To evaluate the sensitivity of the  subgrid-scale-modeling  quality  on

Revision as of 07:53, 28 April 2011


Front Page

Description

Test Data

CFD Simulations

Evaluation

Best Practice Advice

SANDIA Flame D

Application Area 2: Combustion

Application Challenge AC2-09

Abstract

This document contains the specifications of the Application Challenge proposed by the team of the Institute of Thermal Machinery, Cz?stochowa University of Technology. This team performed LES predictions of the Sandia Flame D within the EU-project MOLECULES FP5, Contract N° G4RD-CT- 2000-00402. The computations were performed with the BOFFIN-LES code developed at Imperial College by the group of Professor W.P. Jones. The software for the Conditional Moment Closure model used in calculations was developed by Professor E. Mastorakos at Cambridge University and implemented in the BOFFIN-LES code by the team of the Institute of Thermal Machinery.

   Sandia Flame D is a  widely  used  test  case  for  the  validation  of
   numerical models of non-premixed  combustion.  This  flame  is  of  the
   flamelet regime type in which  a  scale  separation  appears  i.e.  the
   smallest scales of the  turbulent  flow,  the  Kolmogorov  scales,  are
   significantly larger than the scales characteristic  for  the  reaction
   zone.   Such   a   flame   facilitates   the   study   of   models   of
   turbulence/chemistry interaction, allowing to separate the influence of
   turbulence  and  turbulence/chemistry  interaction  models   from   the
   influence of chemical kinetics models applied. Non-premixed  combustion
   is limited by turbulent mixing and dominated by large scale structures.
   The quality of unsteady flow dynamics predictions seems to  be  crucial
   for the quality of the overall combustion process. Hence,  within  this
   document attention is restricted to LES calculations and  neither  RANS
   nor URANS predictions are included or analyzed.
   To evaluate the sensitivity of the  subgrid-scale-modeling  quality  on
   turbulent combustion predictions, two subgrid-scale models were tested:
   the classical Smagorinsky  model and the  dynamic   version.  Turbulent
   mixing features are then transmitted  to  the  reaction  front  through
   turbulence/combustion  interaction  models  that  also  influence   the
   overall  combustion  process  predictions.   As   turbulence/combustion
   interaction model, two different approaches were  studied:  the  simple
   and efficient steady flamelet model and the  more  advanced  simplified
   Conditional  Moment  Closure-CMC  (In  simplified  CMC  approach,   the
   convective terms in physical space were  neglected,  making  the  model
   very close to the unsteady flamelet approach).
   DOAPS for this type of reacting flow are  velocity,  mixture  fraction,
   temperature and species concentration  mean  and  fluctuating  profiles
   quantified by their local maxima.




Contributed by: Andrzej Boguslawski — Technical University of Czestochowa

Front Page

Description

Test Data

CFD Simulations

Evaluation

Best Practice Advice


© copyright ERCOFTAC 2011