Jump to navigation Jump to search
Line 20: Line 20:
Thermal Machinery.
Thermal Machinery.


    Sandia Flame D is a  widely  used  test  case  for  the  validation  of
Sandia Flame D is a  widely  used  test  case  for  the  validation  of
    numerical models of non-premixed  combustion.  This  flame  is  of  the
numerical models of non-premixed  combustion.  This  flame  is  of  the
    flamelet regime type in which  a  scale  separation  appears  i.e.  the
flamelet regime type in which  a  scale  separation  appears  i.e.  the
    smallest scales of the  turbulent  flow,  the  Kolmogorov  scales,  are
smallest scales of the  turbulent  flow,  the  Kolmogorov  scales,  are
    significantly larger than the scales characteristic  for  the  reaction
significantly larger than the scales characteristic  for  the  reaction
    zone.  Such  a  flame  facilitates  the  study  of  models  of
zone.  Such  a  flame  facilitates  the  study  of  models  of
    turbulence/chemistry interaction, allowing to separate the influence of
turbulence/chemistry interaction, allowing to separate the influence of
    turbulence  and  turbulence/chemistry  interaction  models  from  the
turbulence  and  turbulence/chemistry  interaction  models  from  the
    influence of chemical kinetics models applied. Non-premixed  combustion
influence of chemical kinetics models applied. Non-premixed  combustion
    is limited by turbulent mixing and dominated by large scale structures.
is limited by turbulent mixing and dominated by large scale structures.
    The quality of unsteady flow dynamics predictions seems to  be  crucial
The quality of unsteady flow dynamics predictions seems to  be  crucial
    for the quality of the overall combustion process. Hence,  within  this
for the quality of the overall combustion process. Hence,  within  this
    document attention is restricted to LES calculations and  neither  RANS
document attention is restricted to LES calculations and  neither  RANS
    nor URANS predictions are included or analyzed.
nor URANS predictions are included or analyzed.


     To evaluate the sensitivity of the  subgrid-scale-modeling  quality  on
     To evaluate the sensitivity of the  subgrid-scale-modeling  quality  on

Revision as of 07:50, 28 April 2011


Front Page

Description

Test Data

CFD Simulations

Evaluation

Best Practice Advice

SANDIA Flame D

Application Area 2: Combustion

Application Challenge AC2-09

Abstract

This document contains the specifications of the Application Challenge proposed by the team of the Institute of Thermal Machinery, Cz?stochowa University of Technology. This team performed LES predictions of the Sandia Flame D within the EU-project MOLECULES FP5, Contract N° G4RD-CT- 2000-00402. The computations were performed with the BOFFIN-LES code developed at Imperial College by the group of Professor W.P. Jones. The software for the Conditional Moment Closure model used in calculations was developed by Professor E. Mastorakos at Cambridge University and implemented in the BOFFIN-LES code by the team of the Institute of Thermal Machinery.

Sandia Flame D is a widely used test case for the validation of numerical models of non-premixed combustion. This flame is of the flamelet regime type in which a scale separation appears i.e. the smallest scales of the turbulent flow, the Kolmogorov scales, are significantly larger than the scales characteristic for the reaction zone. Such a flame facilitates the study of models of turbulence/chemistry interaction, allowing to separate the influence of turbulence and turbulence/chemistry interaction models from the influence of chemical kinetics models applied. Non-premixed combustion is limited by turbulent mixing and dominated by large scale structures. The quality of unsteady flow dynamics predictions seems to be crucial for the quality of the overall combustion process. Hence, within this document attention is restricted to LES calculations and neither RANS nor URANS predictions are included or analyzed.

   To evaluate the sensitivity of the  subgrid-scale-modeling  quality  on
   turbulent combustion predictions, two subgrid-scale models were tested:
   the classical Smagorinsky  model and the  dynamic   version.  Turbulent
   mixing features are then transmitted  to  the  reaction  front  through
   turbulence/combustion  interaction  models  that  also  influence   the
   overall  combustion  process  predictions.   As   turbulence/combustion
   interaction model, two different approaches were  studied:  the  simple
   and efficient steady flamelet model and the  more  advanced  simplified
   Conditional  Moment  Closure-CMC  (In  simplified  CMC  approach,   the
   convective terms in physical space were  neglected,  making  the  model
   very close to the unsteady flamelet approach).
   DOAPS for this type of reacting flow are  velocity,  mixture  fraction,
   temperature and species concentration  mean  and  fluctuating  profiles
   quantified by their local maxima.




Contributed by: Andrzej Boguslawski — Technical University of Czestochowa