Revision as of 10:24, 29 March 2010

Front Page

Description

Test Case Studies

Evaluation

Best Practice Advice

References

Axisymmetric buoyant far-field plume in a quiescent unstratified environment

Underlying Flow Regime 1-06

Test Case

Brief Description of the Study Test Case

The experiments used in this UFR are those of George et al. [3] which were conducted in 1974 at the Factory Mutual Research Corporation and were subsequently repeated by Shabbir & George [34] at the University of Buffalo.

  • Heated air is discharged through a circular orifice into ambient air that is at rest.
  • The plume source temperature is 300°C and the ambient air is 29°C.
  • The source has diameter, D = 6.35 cm.
  • The hot air is discharged at a velocity of U0 = 67 cm/s with a approximately a top-hat profile.
  • Temperature and velocity fluctuations at the inlet are less than 0.1%.
  • George et al. [3] present experimentally measured profiles

of both mean and fluctuating components of the temperature and axial velocity in the self-similar region at x/D = 8, 12 and 16 above the source.

Test Case Experiments

The experiments used in this UFR are those of George et al[3] which were conducted in 1974 at the Factory Mutual Research Corporation and were subsequently repeated by Shabbir & George [34] at the University of Buffalo.


The general arrangement is shown in Figure 4. Compressed air is passed through a set of heaters and porous mesh screens before exiting through a nozzle into the enclosure. The nozzle is stated as a 15:1 contraction in [3], a 12:1 contraction in [sg92] and appears to be different again in a drawing of the arrangement in [3] (see Figure 5). It resulted in a velocity profile through the exit which was uniform to within 2% outside the wall boundary layer. The velocity and temperature fluctuations at the exit were measured to be very low, less than 0.1% in [3] and 0.5% in [34]. The temperature of the source was 300°C and the ambient environment 29°C. Both were controlled to an accuracy of within 1°C. The discharge velocity was 67 cm/s, as calculated from the measured heat flux. These source conditions corresponded to Reynolds number, Re0 = 870, and densimetric Froude number, Fr0 = 1.23 [#sdfootnote1sym 1]. There was no evidence of laminar flow behaviour at a position two inlet diameters downstream from the source. The effective origin of the plume, x0, was found to be at the same location as the exit (see [3] for details of how this was determined).


The screen enclosure around the plume exit was 2.44 × 2.44 metres in cross-section and 2.44 metres high (there is, presumably, an error in [3] which suggests that the enclosure is 2.44 × 2.44 × 2.44 mm). In the later Shabbir & George experiments, a 2 × 2 × 5 metre enclosure was used. The purpose of the screens was to minimize the effect of cross-draughts and other disturbances affecting the flow. Two-wire probes were used by George et al[3] to record velocities and temperature.

[#sdfootnote1anc 1]The densimetric Froude number is calculated here from the source and ambient temperatures, the exit velocity and source diameter given by George et al. [gat77], using Equation (1). However, George et al. [gat77] stated that the densimetric Froude number was 1.4. It is unclear how they determined this value. Using the approach taken by Chen & Rodi [cr80] in which the source density instead of the ambient density is used to make the density difference dimensionless, and Froude number is defined using the square of the expression given in Equation (1), this gives a Froude number of 0.80.


UFR1-06 figure5.gif
Figure 5 Schematic of the George et al. [3] experiments, from Shabir & George [11]


UFR1-06 figure6.gif
Figure 6 Schematic of the plume generator used in the experiments, from George et al. [3]


George et al[3] reported that measurement errors, stemming from directional ambiguity of the hot wire and its thermal inertia, were around 3% for the velocity and lower for other mean and RMS values. The frequency response of the hot wires was estimated to be around 300 Hz compared to the frequency of the energy-containing eddies at around 50 Hz and the Kolmogorov microscale at 1 Khz. It was noted that measurement errors were likely to be higher on the outer edge of the plume where the velocity fluctuations were higher.


In their review of plume experiments, Chen & Rodi [1] noted that the data from George et al. differed significantly from earlier measurements by Rouse et al[64]. However, they considered it to be more reliable due to its use of more sophisticated instrumentation. George [40], describes an experimental program at the University of Buffalo that was set up following publication of the original George et al. [3] paper to investigate possible causes of differences in experimental plume results. Possible sources of errors discussed included:

  • ambient thermal stratification
  • the size of the enclosure
  • the use of porous screens used to minimise disturbances from the far-field affected the plume source.
  • hot wire measurement errors


The most significant concern was ambient thermal stratification. One of the features of buoyant plumes in neutral environments is that the integral of the buoyancy across the whole cross-section of the plume, F, should remain constant and equal to the buoyancy added at the source, F0. George [40] discussed how thermal stratification involving small temperature differences of the order of 1°C across a 3 metre vertical span would be sufficient to cause F to decrease to only 50% of the source value. This would be likely to cause differences in measured temperature and velocity plume profiles.


In the initial experiments of George et al[3], the thermal stratification was not strictly controlled. However, results from later experiments published in the PhD thesis of Shabbir [32] (reproduced in  [34] and  [40]), which conserved buoyancy to within 10%, are in good agreement with the earlier results from George et al[3]. This suggests that, perhaps fortunately, ambient thermal stratification did not contaminate the George et al[3] results significantly.


A summary of the original results from George et al[3] and those reproduced later by Shabbir & George [11] is presented in Table 3. Also shown are the recommended values from Chen & Rodi's review [1] and other studies. The parameters given in Table 3 relate to the following empirical formulae for the mean vertical velocity:


and effective buoyancy acceleration:


where and are Gaussian functions:



The parameters, and are the dimensionless half-widths of the plume, as defined by the location where the normalized buoyancy or mean velocity falls to half its centreline value. The RMS temperature and axial velocity fluctuations normalized by their centreline mean values are denoted, and , respectively.


As noted earlier, Dai&nbspet al. [10][37] [38][39][41] disputed the accuracy of the George et al. [3] experiments and suggested that they had made measurements too near the source, before the plume had reached a fully-developed state. Their arguments are disregarded by Shabbir & George [11] [34].


Table 3

CFD Methods

Van Maele & Merci: Description of CFD Work

Numerical Methods

Van Maele & Merci [2] used the finite-volume-based commercial CFD code, Fluent, to simulate the plume experiments of George et al. [3]. For the discretization of the convective terms in the momentum, turbulence and energy equations a second-order upwind scheme was used. Diffusion terms were discretized using second-order central differences and the SIMPLE algorithm was used for pressure-velocity coupling. The flow was treated as axisymmetric and elliptic calculations were performed used a Cartesian grid arrangement.


The low-Mach-number form of the Favre-averaged Navier-Stokes equations were used. In this weakly-compressible approach, the density is treated as only a function of temperature and not pressure. Pressure only affects the flow field through the pressure-gradient term in the momentum equations. The ideal gas law is used to link the mean density, , to mean temperature, T as follows:



where p* is taken as constant and equal to the atmospheric pressure. The low-Mach-number approximation implies that the effect of the mean kinetic energy and the work done by viscous stresses and pressure are negligible in the energy equation.

Turbulence Modelling

Two turbulence models were used by Van Maele & Merci [2]: the standard k – ε model of Jones & Launder [65] and the realizable k – ε model of Shih et al. [66]. In the former model, the eddy viscosity is given by:



where cμ is a constant equal to 0.09 and the standard k and ε equations are written:




where cε1 = 1.44, cε2 = 1.92, σk = 1.0, σε = 1.3 and Pk is the production term due to mean shear. The terms G and SεB are source terms related to the influence of buoyancy on the k and ε equations. The treatment of these gterms is discussed below.


The Shih et al. [66] model involves two changes to the standard k – ε model. Firstly, cμ is made a function of strain and vorticity invariants to ensure that the model always returns positive normal Reynolds stresses and satisfies the Schwarz inequality for the turbulent shear stresses. The function form of cμ is given by:



Front Page

Description

Test Case Studies

Evaluation

Best Practice Advice

References


Contributed by: Simon Gant — Lea Associates