UFR 1-07 Evaluation

From KBwiki
Jump to navigation Jump to search


Front Page

Description

Test Case Studies

Evaluation

Best Practice Advice

References

Unsteady Near-Field Plumes

Underlying Flow Regime 1-07


Comparison of DesJardin et al. [1] CFD Calculations with Experiments

Figure 11 shows a snapshot of the flow field predicted by the CFD model of DesJardin et al. [1]. With the coarse grid, the plume puffing frequency was found to be approximately 1.8 Hz, much higher than the frequency measured in the experiments of 1.37 Hz. The predictions improved as the grid was refined, with the fine grid producing a frequency of 1.5 Hz. A similar frequency was obtained with or without an SGS model. DesJardin et al. [1] also presented results from a simulation with no SGS model and a very coarse mesh (220k nodes in total and only 30 cells across the source diameter). This produced a puffing frequency of 1.7 Hz, which they considered to be an adequate estimate for engineering purposes, although the axial velocity in this case was overpredicted by nearly a factor of two.


UFR1-07 fig11.png


Figure 11  An instantaneous snapshot of the DesJardin et al.‘s LES predictions showing an iso-contour of vorticity magnitude at 5% of the maximum coloured according to the magnitude of the gravitational torque.


Figure 12 shows the mean axial velocity predictions at three vertical positions within the plume. The symbols are the experimental data points with their uncertainty shown as vertical lines. The predictions are overall in good agreement with the experiments. All of the results are mostly within the experimental uncertainty bounds except for the results obtained using the coarse 512k node mesh with an SGS model. For this case, the peak velocity is overpredicted by 27 %, 61 % and 67 % at the three downstream positions x = 0.2 m, 0.4 m and 0.6 m. For the coarse mesh, mean axial velocity predictions are improved when the SGS model is not used. DesJardin et al. suggested that the relatively poor predictions with the coarse grid and SGS model were due to there being a net upscale transport of turbulent energy near the plume source, from small to large scales. They noted that the purely dissipative Smagorinsky model was unable to account for this phenomenon. Using finer meshes, a greater proportion of turbulence energy was resolved. Alternatively, by removing the SGS model, the damping from the turbulence model was reduced, which improved the predictions.


UFR1-07 fig12left.gif
UFR1-07 fig12right.gif
Figure 12  Mean axial velocity (left) and radial velocity (right) at three axial locations: 0.2 m (top), 0.4 m (middle) and 0.6 m (bottom).


The radial mean velocity predictions (Figure 12) show reasonable agreement with the experiments on the periphery of the plume but all of the simulations overpredict the radial velocity near the plume centreline. The best results are again achieved using the finer mesh.


RMS axial velocity profiles are shown in Figure 13. The coarse-grid results without the SGS model and the results on the fine grid with or without the SGS model all overpredict the RMS velocities by up to 75%. The best agreement is obtained with the coarse-grid using the SGS model. DesJardin et al. suggested that the relatively good performance for this last case is purely fortuitous and is due to excessive damping of the turbulent fluctuations. The generally poor predictions of the RMS velocity was attributed to under-resolution of the turbulent production and destruction near the base of the plume, resulting in an overly-coherent puffing motion. Radial RMS velocities (not shown) were better predicted, with fine-grid simulations falling within the experimental uncertainty bounds.


Figure 13 also shows the predicted and experimental mean helium mass fractions at the three downstream positions. The best predictions were obtained using the fine mesh without the SGS model, which were within the experimental uncertainty bounds for the two positions nearest the plume source. The worst results were obtained using the coarse-grid with the SGS model which overpredicted the experimental values by nearly a factor of two. The mean helium concentration decayed faster in the experiments than in the simulations, producing worsening agreement between experiments and simulations with increasing distance from the source.


UFR1-07 fig13left.gif
UFR1-07 fig13right.gif
Figure 13  RMS axial velocity (left) and mean helium mass fractions (right) at three axial locations: 0.2 m (top), 0.4 m (middle) and 0.6 m (bottom).


DesJardin et al. [1] also presented predicted RMS concentration fluctuations which showed significant grid sensitivity and poor overall agreement with the experiments (errors of up to 200%). This was attributed to the sensitivity of the concentration fluctuations to the small scales of motion that were not resolved by the LES. They suggested that the RMS velocity fluctuations did not show the same degree of sensitivity due to the smoothing effect of the pressure gradient in the momentum equation. The poor prediction of the concentration fluctuations has important implications for fire simulations, where the mixing of fuel and air determines the overall heat release rate.


Comparison of Tieszen et al. [2] CFD Calculations with Experiments

Tieszen et al. [2] performed grid sensitivity tests using three different meshes, with 0.25M, 1M and 4M nodes. As the mesh density was increased, the amount of air entrained into the plume increased, which increased the centreline density. The best agreement between the CFD predictions and the experimental data was obtained using the finest mesh (see Figures 15 and 16). Analysis of the CFD results indicated that underprediction of entrainment with coarse grids was related to overprediction of the axial velocity near the plume source. Surprisingly, the mean radial velocity did not show significant sensitivity to the grid density. Coarse grids were found to produce overly-high resolved turbulent kinetic energy along the plume centreline, i.e. puffs that were too strong. Tieszen et al. [2] commented that this finding was consistent with a lack of mixing associated with plume puffing that was overly coherent (i.e. a lack of interaction between small and large scales).


UFR1-07 fig14.gif
Figure 14 Instantaneous density contours with the 250k node mesh (left) and 4M node mesh (right), from Tieszen et al. [2]



UFR1-07 fig15.gif
Figure 15 Mean density contours: simulations with 250k nodes (upper-left), 1M nodes (upper-right) and 4M nodes (lower-left); experiments (lower-right). From Tieszen et al. [2].



UFR1-07 fig16.gif
Figure 16 Mean axial velocity contours (in m/s): simulations with 250k nodes (upper-left), 1M nodes (upper-right) and 4M nodes (lower-left); experiments (lower-right).From Tieszen et al. [2].


Comparison of Xin [3] CFD Calculations with Experiments

In the simulations of Xin [3], the mean axial velocity was overpredicted at all measurement positions (Figure 17). The error increased with distance from the nozzle, approaching a factor of nearly 2 at \textit{x}/\textit{D} = 0.8. This behaviour is consistent with the findings of Tieszen \textit{et al}. [2] and Chung \& Devaud [39], that relatively coarse meshes lead to overprediction of the axial velocity. Significantly better mean velocity predictions were obtained by Chung \& Devaud [39] using the same code with grid cells half the width.

The results from s\textup{imulations undertaken with and without the baroclinic torque term showed that the mean axial velocity increased slightly when the term was included (Figure 17). This coincided with an increase in radial velocity close to the base of the plume. Neglecting the baroclinic torque produced lower helium mass fractions (Figure 18). The experimental mass fraction values were not shown for comparison in Xin{\textquotesingle}s paper. Comparing instead with the results shown in DesJardin }\textit{et al}\textup{. }\textup{[1]}\textup{ (see Figure 13), it appears that the mean concentrations decayed faster in the experiments than in the simulations. Overall, the results without the baroclinic torque were probably closer to the experiments than those with the term.}


Front Page

Description

Test Case Studies

Evaluation

Best Practice Advice

References


Contributed by: Simon Gant — UK Health & Safety Laboratory

© copyright ERCOFTAC 2010