Silver:UFR 2-07 Quality Review: Difference between revisions

From KBwiki
Jump to navigation Jump to search
(New page: {{UFR|front=UFR 2-07|description=UFR 2-07 Description|references=UFR 2-07 References|testcase=UFR 2-07 Test Case|evaluation=UFR 2-07 Evaluation|qualityreview=UFR 2-07 Quality Review|bestp...)
 
Line 1,023: Line 1,023:
 
 


</div>
 


<font size="-2" color="#888888">© copyright ERCOFTAC 2004</font><br />
<font size="-2" color="#888888">© copyright ERCOFTAC 2004</font><br />
Line 1,029: Line 1,029:
----
----


<br />
{| width="100%"
|- valign="top"
| width="500" align="left" |
<div id="text"><font size="-1">


Contributors: William Anderson - ALSTOM Power (Switzerland) Ltd
Contributors: William Anderson - ALSTOM Power (Switzerland) Ltd

Revision as of 14:23, 5 March 2009


Front Page

Description

Test Case Studies

Evaluation

Best Practice Advice

References




3D flow around blades

Underlying Flow Regime 2-07               © copyright ERCOFTAC 2004


Quality Review

INSTRUCTIONS TO THE REVIEWER

Please indicate your agreement or disagreement with the comments below, by ticking either the YES or NO box (using symbol þ). If you would like to comment on any of the questions, please also tick the CO (comment) box, and add your comments in the box provided at the end of each section. Please make sure that all questions are answered.

 

When you have completed the review, please indicate below your overall judgment of the UFR and its documentation:

 

 

Accept þ

 

 

Reject

 

 

Accept provided the following conditions are met

 

 

 

 


 

Underlying Flow Regime Title: 3D around the blades

UFR Author and UFR number: UFR 2-07 

'Reviewer (Name/Organisation) :' Marc Demoulin/ Partner 06 Renault

 

 

1

 

TOP LEVEL CHECK

 

YES
 
NO
 
CO
 

1. 1

Is the selected test-case study a good representation of the assigned UFR?

þ
q
q

1. 2

Does the test-case study include both flow measurements and CFD calculations?

þ
q
q

1. 3

Does the document under review comply with the D32 template

þ
q
q

1. 4

Should any parts be expanded, condensed or deleted?

þ
q
q

1. 5

Are the illustrations and their captions clear and informative?

þ
q
q

1. 6

Are the references adequate and complete?

q
þ
q

1. 7

If any hyperlinks are used, do these function correctly?

q
þ
q

 

 

 
 
 

Comments:

 

 

 

 

 

 

 

 

 


 

 

 
DETAILED CHECK

 

2

 

REVIEW OF UFR STUDIES AND CHOICE OF TEST CASE

 

YES
 

NO

 

CO
 

2. 1

Have past studies of the UFR been reviewed adequately?

q
q
þ

2. 2

Is the chosen test-case study selected from an established database or comparison exercise?

þ
q
q

2. 3

Have the test-case experiments been devised for CFD validation?

þ
q
q

 

 

 
 
 

Comments:

 

More studies related to the UFR could have been reviewed.

 

 

3

 

DESCRIPTION OF THE STUDY TEST CASE

 

YES

 

NO

 

CO

 

3. 1

Is the geometry described adequately, including an appropriate sketch?

þ
q
q

3. 2

Are the flow parameters defining the flow regime specified?

þ
q
q

3. 3

Are the principal measured quantities (i.e. those by which success or failure of CFD is to be judged) specified?

þ
q
q

3.4

Is the description fully self-contained and sufficiently detailed ? (the level of detail required depends on whether a hyperlink to a detailed database is provided)

þ
q
q

 

 

 

 
 

Comments:

 

 

 

 

 


 

4

 

Test CASE EXPERIMENTS

YES
 

NO

 

CO
 

4. 1

Is the test-case facility described adequately?

þ
q
q

4. 2

Are the measurement techniques explained?

þ
q
q

4. 3

Is the quality/accuracy of the measured data discussed?

q
þ
q

4. 4

Are the following quality aspects addressed in this discussion :-

 
 
 

a)

Closeness of flow to target/design conditions?

þ
q
q

b)

Accuracy estimation of measured quantities?

þ
q
q

c)

Checks on global conservation of conserved quantities?

q
þ
q

d)

Consistency in the measurements of different quantities?

q
þ
q

e)

Other (briefly describe)

 
 
q

4. 5

Is the evidence of data quality judged to be sufficient?

q
þ
q

4. 6

Is the information provided at the flow boundaries sufficient to specify or estimate reasonably well the boundary conditions required for a CFD calculation?

q
þ
þ

4. 7

Is the overall discussion self-contained and sufficiently detailed? (the level of detail required depends on whether a hyperlink to a detailed database is provided)

þ
q
q

 

 

 

 

 

Comments:

 

 

 

4.6 the information provided at the flow boundaries are sufficient to specify the boundary conditions, but the accuracy is not sufficient (blockage effects near the wall)

 

 
 
 


 

5

 

CFD METHODS

YES
 

NO

 

CO
 

5. 1

Is an overview given of the methods used?

þ
q
q

5. 2

Have the following aspects of the methods used been explained adequately:-

 
 
 

a)

The codes employed?

q
þ
q

b)

The turbulence/physical models used?

þ
q
q

c)

The wall treatments applied?

þ
q
q

d)

The numerical boundary conditions?

þ
q
q

5. 3

Are comments made on how well the boundary conditions replicate conditions in the test rig?

þ
q
q

5. 4

Is the quality of the calculations discussed?

þ
q
q

5. 5

Are the following quality aspects addressed in this discussion?

 
 
þ

a)

The discretisation scheme(s) and solver(s)?

þ
q
q

b)

The sufficiency of grid resolution(s) ?

q
q
þ

c)

Sensitivities to uncertainties in the boundary conditions

q
q
þ

d)

Comparisons between separate calculations using the same physical model

q
þ
q

e)

Other (briefly describe)

 

 

 

 
 
q

56

Is the evidence of CFD quality judged to be sufficient in all cases?

q
q
þ

 

 

 
 
 

Comments:

 

Meshing influence: the only indication is that the grid used is finer than finer than ref 5.

 

 
 
 

 


 

6

 

COMPARISON OF CFD CALCULATIONS WITH EXPERIMENT

YES
 

NO

 

CO
 

6. 1

Are key comparisons of CFD results with experiment presented in the form of tables or plots?

þ
q
q

6. 2

Do these comparisons include the assessment quantities?

q
þ
q

6. 3

Are further comparisons available via hyperlinks to a results database?

q
þ
q

6. 4

Is the performance of the CFD calculations judged by comparison with experiments discussed and analysed in all cases?

þ
q
þ

 

 

 
 
 

Comments:

 

*Only one comparison CFD calculations/experiments was analysed

 
 
 
 

 

 

7

BEST PRACTICE ADVICE FOR THE UFR

 

YES
 

NO

 

CO
 

7. 1

Are model abilities for this test case discussed and analysed in sufficient detail?

q
q
þ

7. 2

Are recommendations provided on which models should be used for this UFR?

þ
q
q

7. 3

Are these recommendations supported by the evidence?

q
þ
q

 

 

 
 
 

Comments:

 

The BPA presented are only non-recommendation related only to the outlet BC and the radial equilibrium model.

 
 
 
 
 

 


© copyright ERCOFTAC 2004



Contributors: William Anderson - ALSTOM Power (Switzerland) Ltd


Front Page

Description

Test Case Studies

Evaluation

Best Practice Advice

References