Test Case AC3-08

From KBwiki
Jump to navigation Jump to search

Spray evaporation in turbulent flow

Application Challenge 3-08 © copyright ERCOFTAC 2004


Overview of the Experiments

For allowing a detailed analysis of the different effects on spray evaporation several sets of measurements were performed. The geometry is specified in Fig. 1. Heated air was injected through an annulus with 64 mm outer diameter and the diameter of the nozzle holder was 20 and 40 mm, respectively. The test section had a diameter of 200 mm and the length was 1500 mm. The first flow condition considered in the studies was a single phase flow case (i.e. without the liquid spray being operated, see Table 1) in order to assess the flow characteristics and quality of the established air flow and the effect of the spray and the evaporation on the flow (i.e. two-way coupling). The air velocity profiles were obtained by Laser-Doppler anemometry. For this purpose the flow was seeded with 1.5 mm tracer particles. It should be noted that in the two-phase flow (i.e. with operating spray) the gas phase velocity could not be measured since the probability of droplets with diameters less than 5 mm was extremely low to yield reliable measurements. The two-phase flow (i.e. only the droplet properties were determined) was examined for four flow conditions with different air flow rates, air temperatures, liquid flow rates, and diameters of the nozzle holder (Sommerfeld and Qiu 1998). The main parameters for the different experimental conditions are summarised in Table 1. The droplet phase properties (i.e. droplet size, velocity and mass flux) were measured at several cross-sections downstream of the inlet, namely at 25, 50, 100, 200, 300, and 400 mm. Phase-Doppler anemometry (PDA) was applied to obtain the spatial change of the droplet size spectrum in the flow field and to measure droplet size-velocity correlations. The measurement size range was up to 115 mm with equidistant size classes of 5 mm. A description of the test case, the liquid properties, and the data is also available at:


http://www-mvt.iw.uni-halle.de/english/index.php?test_cases.


Table 1. Flow conditions for the considered single- and two-phase flows
Case Diameter nozzle holder Air volume flow rate Air mass flow rate Maximum air velocity Air temperature Flow Reynolds number Liquid mass flow rate Liquid temp. at nozzle exit
(mm) (m3/s) (g/s) (m/s) (°C) (g/s) (°C)
Single phase 40 0.032 29.0 18.0 100 8,577
1 40 0.034 32.6 18.0 80 10,024 0.44 32
2 40 0.031 28.3 18.0 100 8,309 0.44 34
3 40 0.015 14.2 9.0 80 4,422 0.44 32
4 20 0.023 21.2 9.0 100 6,165 0.83 34




Inlet and Boundary Conditions

For all the test cases listed in Table 1, the air flow rate was determined from the integration of the axial velocity profile at the inlet and the associated mass flow rate was determined by multiplication with the air density resulting from the average inlet temperature (i.e. T = 353 K: r = 0.967 kg/m3; T = 373 K: r = 0.915 kg/m3). The liquid flow rate was obtained using a flow meter. The data for all the test cases include profiles of all the components of the gas velocity at the inlet. Profiles of the gas temperature at the air inlet were measured, but it can be assumed to be constant across the annular jet according to the air temperature specified in Table 1. These data are only provided for the single phase flow case. Moreover, Table 1 provides the flow Reynolds number determined with the test section diameter and the air flow properties at the inlet, namely air flow rate, density and dynamic viscosity (i.e. T = 353 K: m = 20.9×10-6 Ns/m2; T = 373 K: m = 21.7×10-6 Ns/m2). The droplet phase properties were measured 8 mm downstream of the nozzle exit (i.e. 3 mm downstream of the edge of the nozzle holder). The data include profiles of the mean and RMS velocity components, the droplet mass flux, and the characteristic droplet mean diameters. These inlet profiles are obtained over the entire droplet size spectrum. Additionally, droplet size distributions and size-velocity correlations are given for several radial distances. The number averaged droplet diameter at the inlet was about 20 mm for all cases. For specifying appropriate wall boundary conditions also the outer wall temperature along the test section was measured for the single- and two-phase flow (see: http://www-mvt.iw.uni-halle.de/english/index.php?test_cases).


Thermodynamic Properties of Fluids

All of the liquid and vapour properties and the required correlation for isopropyl alcohol are summarised below.

Viscosity:

The temperature dependence of the viscosity of the gaseous isopropyl may be obtained by the method of corresponding states. From the VDI-Wärmeatlas Blatt Da 25, one obtains the following equation for the viscosity in [Pa s]:

With the normalised temperature Tr = T/Tcrit (Tcrit is the critical temperature given at the end of this section), one obtains:

and the factor x is calculated from:



The constant fp which has to be considered for polar gases is fp = 1.141824 for isopropyl.

Special heat capacity:

The specific heat capacity [kJ/(kg K)] of isopropyl vapour is calculated according to the ideal gas assumption (VDI Wärmeatlas, Blatt Da 21) with the equation:



The values of Ai, Bi, Ci and Di for the individual elements of isopropyl are listed in Table 2.


Table 2 Constants for CH3, CH and OH; Isopropyl alcohol: ((CH3)2 CH OH)
A B C D
CH3 0.6087 2.1433 -0.0852 0.1135
CH -3.5232 3.4158 -0.2816 0.8015
OH 6.5128 -0.1347 0.0414 -0.1623




The heat capacity of the liquid isopropyl is obtained by (VDI Wärmeatlas, Blatt Da 23):


with ω = 0.669 and Rm = R/M being the specific gas constant.

The heat capacity of air (mixture of nitrogen and oxygen) was calculated according to Perry (1984):

Thermal conductivity:

For isopropyl alcohol, the thermal conductivity in [kW/(m K)] is calculated from:


with:

a = 1.067

cir = 4.38

cv = cp M - R

The thermal conductivity [W/(m K)] for air is obtained from:


with: λair(373 K) = 0.03139


Vapour pressure:

The vapour pressure for isopropyl is obtained from the Clausius-Clapeyron relation:


where DHv is the latent heat of vaporisation at temperature T which may be obtained from:


Failed to parse (SVG (MathML can be enabled via browser plugin): Invalid response ("Math extension cannot connect to Restbases.") from server "https://en.wikipedia.org/api/rest_v1/":): {\displaystyle \[\Delta H_{v}{(T)} = \Delta H_{v}{(T_{ref})} - \left(\frac{1-T/T_{c}}{1-T_{ref}/T_{c}}\right)^{0.38}\]}


with: DHv (355) = 666.4 kJ/kg (Perry, 1984).


Coefficient of binary diffusion:

The coefficient of binary diffusion for isopropyl in air was measured for different temperatures (e.g. Vargaftik, 1983). The following correlation may be used:

Failed to parse (syntax error): {\displaystyle \[D = 4.7010^{-10} T^{1.75}_{av}\lfloor m^2/s \rfloor\]}


where Tav is the average temperature in the vapour film around the droplet and may be obtained, for example, by the „1/3“ averaging rule.


Additional properties:

Isopropyl:

Molar mass M 60.09 kg/kmol

Tcrit 508.3 K

Pcrit 48.2 bar

r1 (liquid) 785 kg/m3

Air:

Molar mass M 28.84 kg/kmol

Tcrit 132.5 K

Pcrit 37.7 bar

r (373 K) 0.9329kg/m3


Measurement Errors

The air flow rate was determined from the integration of the axial velocity profile at the inlet and the associated mass flow rate was determined by multiplication with the air density resulting from the average inlet temperature. Hence an accuracy of ±10% can be estimated. The liquid flow rate could be adjusted within ±5% by using a flow meter. The velocity measurements of the gas phase were performed by sampling 2,000 signals at each measurement location. Therefore, a high degree of confidence is given. The droplet phase properties were obtained from 20,000 samples over the entire size spectrum ensuring statistical reliable data for the mean properties and the associated rms-values (the mean and rms-values of all velocity components are provided in the database: www-mvt.iw.uni-halle.de/testcases.html). This however implies that the statistical reliability for size dependent properties is lower at the edges of the size distributions. The droplet mass flux could be measured with an accuracy of ±10% if the spray was rather symmetric (Sommerfeld & Qiu 1995).


Experimental results

Profiles of air or droplet phase properties are available at the cross-section 25, 50, 100, 200, 300 and 400 mm downstream of the inlet. For the single phase flow these are the mean stream-wise and radial velocities and the associated rms-values. Additionally, mean temperature profiles of air were measured at the inlet and within the test section using a thermocouple. In the two-phase flow only the spray droplet properties could be measured, namely the stream-wise and radial droplet mean velocities and rms-values, the droplet mass flux, droplet concentration, and several droplet diameters. Additionally, the droplet mass flow rate along the test section was determined from the integration of the droplet flux profiles. These data are a measure of the integral evaporation rates.

For the spray case 4 the highest evaporation rate within the test section was achieved due to high air temperature and low inlet velocity. The mean stream-wise and radial velocity profiles for this case are presented in Fig. 2. The radial velocity could only be measured over half a cross-section, but clearly indicates the spreading of the spray. The axial mean velocity profiles indicate that the spray flow is rather axi-symmetric and that the droplets are continuously decelerated. The profiles of the droplet mass flux (Fig. 3) also are rather symmetric and of course reveal the rather quick evaporation of the droplets in this case. Initially, the flux profiles have two maximum values associated with a hollow cone spray. Finally, Fig. 4 shows the profiles of the droplet number mean diameter and the associated rms-values. Also these profiles are rather symmetric and exhibit the typical shape with large droplets at the edge of the spray. The rms-value shows that in this region the droplet size distributions are rather wide (see also Sommerfeld & Qiu 1998).


Image291.gif


Fig. 2 Profiles of measured axial (a) and radial (b) droplet mean velocities along the test section for case 4


Image292.gif


Fig. 3 Profiles of the measured droplet mass flux along the test section for case 4


Image293.gif


Fig. 4 Profiles of the droplet number mean diameter (a) and the diameter rms-value (b) along the test section for case 4


© copyright ERCOFTAC 2004


Contributors: Martin Sommerfeld - Martin-Luther-Universitat Halle-Wittenberg

Site Design and Implementation: Atkins and UniS

       Top        	      Next