EXP 1-2 Measurement Data and Results

From KBwiki
Jump to navigation Jump to search

Pollutant transport between a street canyon and a 3D urban array as a function of wind direction and roof height non-uniformity

Front Page

Introduction

Review of experimental studies

Description

Experimental Set Up

Measurement Quantities and Techniques

Data Quality and Accuracy

Measurement Data and Results


Measurement data/results

Results

Figs. 1 and 2 show the mean dimensionless total pollution fluxes through the top (at z/H = 0.6) and side openings of the studied street canyons for the vertical (90°) and oblique (45°) wind directions, respectively. The mean dimensionless total vertical pollution fluxes were calculated for the top opening as

, (1)

where c* is the instantaneous dimensionless concentration, c is the instantaneous concentration in ppm, w is the instantaneous vertical velocity component in m s-1, Uref is the reference velocity in m s-1(here the freestream velocity), H is the reference height in m (here the height of the building of uniform roofs), L is the length of the line source in m, Q is the volumetric flow of ethane from the line source in ml s-1, and the overbar denotes the time averaging. Similarly, the mean dimensionless total latera pollution fluxes were calculated for the lateral opening as

, (2)

where v is the lateral velocity component.

Fig. 1a shows that in the case of the uniform roof, the pollutant is transported up the leeward wall and down the windward wall due to the vertical recirculation in the middle of the street canyon. Near the lateral ends of the street canyon, the pollutant is transported by horizontal recirculation, also known as corner vortex. This type of transport can also be observed at the lateral openings of the street canyon. However, in the case of the uneven roof heights, these vortices are either absent altogether, as in the case of the right uneven street canyon (Fig. 1b), or they are enhanced, as in the case of the left uneven canyon (Fig. 1c). Especially near the right lateral end (seen from the downstream) of the left non-uniform canyon, there is a very strong horizontal recirculation that traps the pollutant also at the windward wall (se y = H in Fig. 1c). It can also be seen from Fig. 1 that both the uniform and left non-uniform street canyons have a higher re-emission (negative total pollutant flux) of the pollutant than the right non-uniform canyon and are therefore more poorly ventilated.


Figure 1: Mean dimensionless total pollution flux fields (coloured contours) through the top (c*w/Uref in the middle) and lateral (c*v/Uref, at the sides) of the a) uniform (A1-R) and non-uniform b) right (A2-R) and c) left (A2-L) street canyons for the perpendicular wind direction. The positive and negative values of the fluxes represent the outgoing and incoming flux from/into the canyon, respectively. The grey contour represents the dimensionless height (z/H) of the buildings, where H is the mean urban height.


File:Sketch vortices exp.jpg.jpg
Figure 1: Mean dimensionless total pollution flux fields (coloured contours) through the top (c*w/Uref in the middle) and lateral (c*v/Uref, at the sides) of the a) uniform (A1-R) and non-uniform b) right (A2-R) and c) left (A2-L) street canyons for the perpendicular wind direction. The positive and negative values of the fluxes represent the outgoing and incoming flux from/into the canyon, respectively. The grey contour represents the dimensionless height (z/H) of the buildings, where H is the mean urban height.


When the wind blows at a 45° angle, a spiral vortex is created in the street canyons, carrying the pollutant up the leeward wall and down the windward wall (Fig. 2). But the non-uniformity of the roof height also influences the development of this pollutant transport here. The best ventilated street canyon is now the left non-uniform one, since less pollutant is transported into the canyon through the lateral opening (compare the negative pollutant flows for the left openings of the street canyons).

Figure 2: The same as in Fig. 1 but for the oblique wind direction.

Experimental data for download

The following experimental data are presented in Tecplot block format. Thus, all of the values for the first variable are given in a block, then all of the values for the second variable, then all of the values for the third, and so forth. The normalised time-averaged momentum fluxes (u'w' or u'v') and the turbulent (c'w' or c'v') and total pollution fluxes (cw or cv) are given in angle brackets (< >). The name of the data (zones in Tecplot) reflects the configuration studied, e.g. A2-L_45_z=0.6H stands for the city model A2, the left street canyon (L), the oblique wind direction (45°) and the height of the upper opening (0.6H). The data are packed according to the measured street canyon opening (TOP or LAT) and wind direction (90 degrees or 45 degrees).

The data for the top openings:

media:EXP_data_TOP_90degrees.zip

media:EXP_data_TOP_45degrees..zip

The data for the lateral openings:

media:EXP_dat_LAT_90degrees.zip

media:EXP_data_LAT_45degrees.zip




Contributed by: Štěpán Nosek — Institute of Thermomechanics of the CAS, v. v. i.

Front Page

Introduction

Review of experimental studies

Description

Experimental Set Up

Measurement Quantities and Techniques

Data Quality and Accuracy

Measurement Data and Results


© copyright ERCOFTAC 2024