Data Quality and Accuracy of Measurements

The spray, in the case without the airflow, is axially symmetrical with low residual irregularities on the velocity, droplet size and concentration resulting from the imprints of the two inlet ports.

The tunnel was designed to produce a uniform and low-turbulent air velocity profile at the test section inlet. The velocity profile in the measured position (Figure 13) is uniform with values of ±5% from the nominally set value (8, 16 or 32 m/s) within the positions ±80 mm from the section axis and the velocity continuously decreases towards the walls. The airflow in the test section is symmetrical with respect to the horizontal and vertical axes of the test section, as also seen in Figure 13. The profiles were measured without the atomizer spraying, which strongly affects the local velocity around the spray and behind it. These effects must be considered in the numerical studies.
Several repeated measurements were performed to assess the repeatability of the PDA measurements. Based on these, the measurement errors were estimated (A type of uncertainty estimate). The velocity measurement error was under ±0.3 m/s, the linear average droplet diameter () error was ±1.1 µm, and Sauter mean diameter () error was ±1.8 µm. The PDA system provides velocity and spherical validations whose results are documented in the measurement files. The three photodetector PDA system provides the spherical validation to improve the sizing accuracy by rejecting measurements from signals with phase ratio values lying outside the expected value. With the velocity validation, the PDA system checks the signal quality to ensure that it meets certain criteria, such as the signal-to-noise ratio and the strength of the scattered light signal. It filters out low-quality signals that may result in inaccurate velocity measurements.
The spatial resolution of the HSC is 46 μm/px × 46 μm/px, which restricts its geometric detection limit. Optical distortions of the long-range microscopic lens is negligible compared to other errors. The images were processed to estimate the spray boundary. The standard mean deviation of the spray boundary detection was ±0.55 mm.
The wind tunnel was designed and tuned to provide controlled, repeatable and stable flow with low and flat velocity profile. The flow conditions in the test section of the tunnel were inspected before the measurement with Laser Doppler anemometry. The velocity and were measured in 20 equidistantly spaced positions 150 mm downstream from the inlet of the test section in the case without the atomizer spraying; see Figure 13. The horizontal velocity profiles at three cross-flow velocity cases in the test section are documented there. The error bar width in Figure 13 is, in all cases, smaller than the symbol size. The vertical velocity profiles (not shown here) are symmetrical and similar to the corresponding horizontal profiles. The free-stream is lower than 0.8%. It was computed as the ratio of root mean square cross-flow velocity to average cross-flow velocity. The positioning error of the 3D computer-controlled system used for positioning the wind tunnel body relative to the measurement volume of the PDA was less than 0.1 mm.


Fig13 test.png
Figure 13: Measurement positions, velocity profiles and turbulence intensities for different cross-flow velocities

The uncertainties of the operation conditions of the atomizer, namely the inlet pressure and flow rate of the sprayed water are detailed in the section Atomizer under test and its supply system.

Limitations of the experiment

The experiment is a physical representation of the case of the interaction of a conical liquid sheet with flowing gas. The ideal case represents a steady, continuous discharge of the swirling liquid with the formation of a smooth attenuating sheet. The gas is expected to undergo steady, low-turbulent, incompressible flow with uniform velocity in the far (unaffected) field. The real experiment is provided as a case of confined flow with the boundaries formed by the section walls and corresponding gas flow characteristics as detailed in Section Data Quality and Accuracy of Measurements.
The atomizer was carefully designed and precisely fabricated by machining with the aim to produce stable internal swirling flow and steady discharge (possible effects of fabrication imprecisions are studied in [1]). Also, the water supply system was checked for unwanted pulsations that could propagate from the pump through the pipe to the nozzle. The atomizer showed no unwanted pulsations or fluctuations of the produced liquid sheet or spray.
The walls of the wind tunnel were designed to be sufficiently rigid, and a measurement of the wall vibrations was performed to confirm that no unwanted vibrations were excited by the flow or generated in other ways that could, as a result, affect the flow. Also, the compensator (2) was used to isolate the spreading of the fan vibrations to the tunnel construction. The flow was probed to find any harmful fluctuations, e.g. at the fan blade frequency. This tunnel testing was provided without finding any negative effects, and it is detailed in [2].
The optical techniques for measuring (PDA) and visualisation (HSC) of two-phase flow require visual access to the flow field within the object and a limited distortion of the optical path. The section walls can be considered ideally smooth, planar and forming a rectangular shape. However, the sprayed water can deposit on the side walls and the bottom of the section, which makes them slightly wavy with a height of irregularities in tenths of mm. These deposits formed on the side walls, behind the atomizer, out of the positions of the optical path of both the PDA and HSC systems and did not, therefore, affect the measurements. A sprayed liquid was torn down by the airflow, so the deposits formed behind the spray and their possible effect on the boundary layer of the windows were unimportant. The influence of test section windows on the accuracy of PDA measurement was investigated. The spray produced by an air-brush nozzle was tested for the case with and without the windows present at different arrangements of the PDA. Axial velocity and diameter of droplets were found unaffected by the windows, as detailed in [2].
One limitation of the experiment relies on the measurement network. Even though we made it very detailed, we have not measured, for example, the droplet sizes produced by bag break-up in distant positions from the atomizer.

References

  1. J. Jedelský, M. Malý, M. Bělka, A. Polzer, V. Sámelová, O. Cejpek, and G. Wigley, Journal of Manufacturing Processes 85, 166 (2023)
  2. 2.0 2.1 O. Cejpek, Design and realization of an aerodynamic tunnel for spraying nozzles [online]. Brno, 2020 [cit. 2023-04-18]. Available from: https://www.vutbr.cz/studenti/zav-prace/detail/124871. Master thesis. Brno university of Technology, 2020


Contributed by: Ondrej Cejpek, Milan Maly, Ondrej Hajek, Jan Jedelsky — Brno University of Technology

Front Page

Introduction

Review of experimental studies

Description

Experimental Set Up

Measurement Quantities and Techniques

Data Quality and Accuracy

Measurement Data and Results


© copyright ERCOFTAC 2024