Experiment
When carrying out the experiments, a uniform film of 500 μm thickness is prepared utilizing the film thickness sensor. In the next step, the film thickness sensor is moved and a drop is generated. During the drop impact onto the liquid film shadowgraphy images are taken. A synchronized high-performance LED (Constellation 120E) in combination with a diffuser plate provides a uniform background illumination. Images are taken with a high-speed CMOS camera (Photron SA-X2), recording the impact at a frame rate of 20000 fps with a resolution of 31 μm/px.
The dynamics of the drop-film interaction is characterized by three parameters as indicated in Fig. 4.
- The crown diameter at the crown base dCB, measured 0.13 mm above the film surface
- The crown diameter at the free rim forming the crown top dCT
- The crown height hC
These parameters are obtained from preprocessed images with the help of the MATLAB Image-Processing Toolbox. For this, a background subtraction from raw images is first performed to be able to distinguish the crown from the background. Then the images are binarised, using a global thresholding method, as shown on the left side of Fig. 4. From the evaluation of consecutive binarised images, the temporal evolution of dCB, dCT and hC can be determined. Reflections on the crown surface can lead to nonphysical interpretations of the crowns dimensions in individual frames. To eliminate erroneous values from the results, all values with a deviation of more than three standard deviations from a running median of 20 consecutive frames are considered as outlier.
Numerical method and setup
The numerical simulations are performed with a diffuse-interface phase-field method which solves the coupled Cahn-Hilliard Navier-Stokes equations by a finite volume method using OpenFOAM (code phaseFieldFoam). The computational setup is shown in Fig. 5. In OpenFOAM, axisymmetric calculations are realized by a wedge-shaped domain with small opening angle (Fig. 5 a). The domain size and the initial conditions are displayed in Fig. 5 (b). In the diffuse-interface region, the mesh is adaptive as illustrated in Fig. 5 (c) for the initial configuration. In the azimuthal direction, the wedge is discretized by one mesh cell.
Typical grid resolutions are given and displayed in Section Lib:EXP 1-4 Measurement Data and Results. .
Further details can be found in the following publication:
M. Bagheri, B. Stumpf, I.V. Roisman, C. Tropea, J. Hussong, M. Wörner, H. Marschall, Interfacial relaxation – Crucial for phase-field methods to capture low to high energy drop-film impacts, Int. J. Heat Fluid Flow 94 (2022) 108943, https://doi.org/10.1016/j.ijheatfluidflow.2022.108943
Contributed by: Milad Bagheri, Bastian Stumpf, Ilia V. Roisman, Cameron Tropea, Jeanette Hussong, Martin Wörner, Holger Marschall — Technical University of Darmstadt and Karlsruhe Institute of Technology