UFR 2-11 Test Case: Difference between revisions

From KBwiki
Jump to navigation Jump to search
Line 153: Line 153:
|ANSYS Germany GmbH, Otterfing||''k – ω'' SST SAS
|ANSYS Germany GmbH, Otterfing||''k – ω'' SST SAS
|1.9||4||0.03||0.03||400
|1.9||4||0.03||0.03||400
|-
|Deutsches Zentrum für Luft und Raumfahrt||SA DDES
|0.5||1||0.03||0.0125||320
|}
|}
<br/>
<br/>

Revision as of 14:27, 6 September 2011

High Reynolds Number Flow around Airfoil in Deep Stall

Front Page

Description

Test Case Studies

Evaluation

Best Practice Advice

References

Flows Around Bodies

Underlying Flow Regime 2-11

Test Case Study

Brief Description of the Test Case

The following presents a precise description of the primary test case, the NACA0021 airfoil at 60° angle of attack.


A visual impression of the geometry and flow has been shown in Figure 1. The experiments were carried out in the wind tunnel of Monash University (see Figure 2). The width of the experimental section is 7.2 airfoil chord lengths, c, and its height is 16c.


UFR2-11 figure2a.jpg|UFR2-11 figure2b.gif
Figure 2: NACA0021 airfoil in wind tunnel (left) and a plan view of wind tunnel (right) [ ]


The airfoil geometry normalized with the chord length, c, is defined by:



Experimental flow parameters, needed to set up appropriate numerical simulations, are presented in Table 2.


Table 2: Flow parameters
Parameter Notation Value
Reynolds number 2.7×105
Chord length 0.125 m
Angle of attack 60°
Free stream Mach number 0.1
Free stream streamwise turbulence intensity 0.6%


The flow parameters measured in the experiments are as follows:

  • Time-averaged pressure coefficient distribution over the airfoil surface, , where is the reference pressure from the undisturbed far-field flow and is the fluid density.


  • Time-averaged sectional drag and lift coefficients, integrated from pressure at individual spanwise locations near the spanwise mid-point: , where and are the sectional pressure drag and lift forces, respectively.


  • Time histories of the sectional lift and drag coefficients (32,000 points total over the time interval T≈9000 (c/U0)).


These data are available on the web site of the DESider EU project [‌5] in digital form: http://cfd.mace.manchester.ac.uk/desider/


Test Case Experiments

A detailed description of the test facility and measurement techniques used in the experiments is given in [‌27, 28]. So here we present only concise information about these aspects of the test case.

As already mentioned, the width of the experimental section is 7.2 airfoil chord lengths c and its height is 16c.The two-dimensionality of the flow over the NACA0021 model was improved by the use of the endplates (see Figure 2). It was found that the free-stream flow has a turbulence intensity of 0.6% and variations of the velocity over the central 0.3m×0.3m area of the test section are less than 3%. During the runs the dynamic pressure was determined by a Pitot upstream of and above the model. This allowed the coefficient of pressure to be determined for each sample. Although the flow decelerates over the distance from the Pitot to the section containing the model, an error in velocity caused by this was less than 6% and was not corrected for.

The aspect ratio of the model was equal to 7.2, which ensured a low value of blockage (6.25% at α = 90°) and is sufficient to minimize possible effects of the finite span on the unsteady flow characteristics [‌27].

The time-averaged pressure coefficient distribution over the airfoil surface was measured with the use of multiple pressure taps arranged in five rows along the model span. In the streamwise direction the taps were concentrated towards the leading edge, which allowed a better resolution of the high pressure gradients in this area. The model was aligned to zero angle of attack by equalizing the pressure on its top and bottom surface. During the runs each tap was sampled at 1000 Hz for 35 seconds and measured pressure signals were corrected for the amplitude and phase response of the tubing. The corrected pressure measurements were fitted with a spline function across the surface for integration of the forces.

The lift and drag were computed from the measured pressures for each time step and then analyzed for frequency content, which resulted in the sectional PSD of the forces. Thus both mean and time-dependent forces are available.

CFD Methods

During the DESider project the considered test case was computed by 8 partners (see Table 3). All the partners used their own flow solvers. Other than that, the difference between the simulations included different grids, somewhat different computational set-ups (e.g. span- sizes of the computational domain), boundary conditions in the span- direction (slip walls or periodic ones), and simulation approaches (DES with different background RANS turbulence models, X-LES [‌8], SAS based on the k – ω SST model [‌12] and k – ω TRRANS model [‌30]). All results were obtained from fully-turbulent computations and the force coefficients were integrated over a single spanwise position (as in the experiment).

The studies performed demonstrated a weak sensitivity of the obtained results to some of the computational parameters. Particularly, only a minor sensitivity of the integral forces and negligible sensitivity of the spectra to the underlying RANS model in DES has been observed in studies by TUB and NTS [‌5, 13, 14]. Similar conclusions have been drawn regarding sensitivity of the CFD predictions to the turbulence modelling approaches that have been used (DES, X-LES, SAS or TRRANS). Other than that, in studies by NTS, the sensitivity to the boundary layer transition treatment, mild variations of the time step size, and the overall grid resolution as well as the resolution of the leading edge curvature have been found to be negligible. Many of these results indicate the weak overall importance of the attached boundary layer prediction, and can be related to the weak effects of Reynolds number and free stream turbulence reported in the experiments.


Table 3: Summary of DESider simulations
Partner Model Grid size (M nodes) z-grid Δt Time sample, Tavg
Lz Δz
ANSYS Germany GmbH, Otterfing k – ω SST SAS 1.9 4 0.03 0.03 400
Deutsches Zentrum für Luft und Raumfahrt SA DDES 0.5 1 0.03 0.0125 320




Contributed by: Charles Mockett; Misha Strelets — CFD Software GmbH and Technische Universitaet Berlin; New Technologies and Services LLC (NTS) and Saint-Petersburg State University

Front Page

Description

Test Case Studies

Evaluation

Best Practice Advice

References


© copyright ERCOFTAC 2024