Test Data AC6-14: Difference between revisions
Line 23: | Line 23: | ||
<div id="figure2"></div> | <div id="figure2"></div> | ||
{|align="center" | {|align="center" | ||
|[[Image:AC6-14_TimisoaraTestRig.jpg|300px]]|[[Image: | |[[Image:AC6-14_TimisoaraTestRig.jpg|300px]]|[[Image:AC6-14_TimisoaraTestRigSchetch.jpg|300px]] | ||
|- | |- | ||
|align="center"|'''Figure 2:''' Photo and schematic view of experimental closed loop test rig from UPT | |align="center"|'''Figure 2:''' Photo and schematic view of experimental closed loop test rig from UPT |
Revision as of 08:43, 11 April 2016
Swirling flow in a conical diffuser generated with rotor-stator interaction
Application Challenge AC6-14 © copyright ERCOFTAC 2024
Overview of Tests
A closed loop experimental test rig was developed and measuresd at the Politehnica University of Timi\c soara, Romania, ~\cite{Resiga2007} for investigating decelerated swirling flows in a conical diffuser and for assessing various flow control methods. The test rig includes the following (see Fig. \ref{circuit}): (i) a main hydraulic circuit, marked blue; (ii) an auxiliary hydraulic circuit, marked red that is implemented in order to assess different control methods ~\cite{Tanasa2013,Bosioc2012}; (iii) a lower reservoir with a volume of 4$\textrm{m}^3$; (iv) a main pump that is able to provide a maximum flow rate of 40 l/s; (v) an upper reservoir equipped with a honeycomb section to provide an uniform flow at the inlet of the swirl test section, and (vi) a test section, marked magenta.
| |
Figure 2: Photo and schematic view of experimental closed loop test rig from UPT |
TEST CASE EXP1
Description of Experiment
Boundary Data
Measurement Errors
Measured Data
References
TEST CASE EXP2
(as per EXP 1)
Contributed by: A. Javadi, A. Bosioc, H Nilsson, S. Muntean, R. Susan-Resiga — Chalmers University of Technology
© copyright ERCOFTAC 2024