=Pollutant transport between a street canyon and a 3D urban array as a function of wind direction and roof height non-uniformity= | =Pollutant transport between a street canyon and a 3D urban array as a function of wind direction and roof height non-uniformity= | ||
{{ | {{EXPHeader | ||
|area=1 | |area=1 | ||
|number=2 | |number=2 | ||
Line 9: | Line 9: | ||
= Measurement data/results = | = Measurement data/results = | ||
==Results== | ==Results== | ||
Figs | [[#figure9|Figs 9]] and [[#figure11|11]] show the mean dimensionless total pollution fluxes through the top (at z/H = 0.6) and side openings of the studied street canyons for the vertical (90°) and oblique (45°) wind directions, respectively. The mean dimensionless total vertical pollution fluxes were calculated for the top opening as | ||
<math>\frac{\overline{c^{*}w}}{U_{ref}} = \frac{\overline{\frac{cU_{ref}HLw}{Q}}}{U_{ref}} = \frac{HL}{Q}\overline{cw}</math>, (1) | <math>\frac{\overline{c^{*}w}}{U_{ref}} = \frac{\overline{\frac{cU_{ref}HLw}{Q}}}{U_{ref}} = \frac{HL}{Q}\overline{cw}</math>, (1) | ||
where <i>c*</i> is the instantaneous dimensionless concentration, <i>c | where <i>c*</i> is the instantaneous dimensionless concentration, <i>c</i> is the instantaneous concentration in ppm, <i>w</i> is the instantaneous vertical velocity component in m s<sup>-1</sup>, <i>U<sub>ref</sub></i> is the reference velocity in m s<sup>-1</sup>(here the freestream velocity), <i>H</i> is the reference height in m (here the height of the building of uniform roofs), <i>L</i> is the length of the line source in m, <i>Q</i> is the volumetric flow of ethane from the line source in ml s<sup>-1</sup>, and the overbar denotes the time averaging. Similarly, the mean dimensionless total latera pollution fluxes were calculated for the lateral opening as | ||
<math>\frac{\overline{c^{*}v}}{U_{ref}} = \frac{\overline{\frac{cU_{ref}HLv}{Q}}}{U_{ref}} = \frac{HL}{Q}\overline{cv}</math>, (2) | <math>\frac{\overline{c^{*}v}}{U_{ref}} = \frac{\overline{\frac{cU_{ref}HLv}{Q}}}{U_{ref}} = \frac{HL}{Q}\overline{cv}</math>, (2) | ||
Line 19: | Line 19: | ||
where <i>v</i> is the lateral velocity component. | where <i>v</i> is the lateral velocity component. | ||
Fig | [[#figure9|Fig 9a]] shows that in the case of the uniform roof, the pollutant is transported up the leeward wall and down the windward wall in the middle of the street canyon due to vertical recirculation (see [[#figure10|Fig 10]]). Near the lateral ends of the street canyon, the pollutant is transported by horizontal recirculation, also known as corner vortex. This type of transport can also be observed at the lateral openings of the street canyon. The pollutant is removed from the street canyon through all openings (top and laterals) mainly by the turbulence, as shown by the relative contribution of turbulent pollutant fluxes to the total fluxes, which is about 70 % (Nosek et al., 2016) and can be calculated from the available data. However, in the case of the uneven roof heights, above mentioned vortices are either absent altogether, as in the case of the right uneven street canyon ([[#figure9|Fig 9b]]), or they are enhanced, as in the case of the left uneven canyon ([[#figure9|Fig 9c]]). In the first case, pollutant transport from the canyon through the openings is mainly driven by the advection, in the second case by the turbulence. Especially near the right lateral end (seen from downstream) of the left non-uniform canyon, there is a very strong horizontal recirculation that also retains the pollutant on the windward wall (se y = <i>H</i> in [[#figure9|Fig 9c]]). It can also be seen from [[#figure9|Fig 9]] that both the uniform and the left non-uniform street canyon have a higher re-emission (negative total pollutant flux) of the pollutant than the right non-uniform street canyon and are therefore worse ventilated. | ||
[[Image:NetFLux_90.jpg|640px|thumb|center|Figure | [[Image:NetFLux_90.jpg|640px|thumb|center|Figure 9: Mean dimensionless total pollution flux fields (coloured contours) through the top (<i><SPAN STYLE="text-decoration:overline">c*w</SPAN>/U<sub>ref</sub></i> in the middle) and lateral (<i><SPAN STYLE="text-decoration:overline">c*v</SPAN>/U<sub>ref</sub></span></i>, at the sides) of the a) uniform (A1-R) and non-uniform b) right (A2-R) and c) left (A2-L) street canyons for the perpendicular wind direction. The positive and negative values of the fluxes represent the outgoing and incoming flux from/into the canyon, respectively. The grey contour represents the dimensionless height (<i>z/H</I>) of the buildings, where H is the mean urban height.]] | ||
<br/> | <br/> | ||
[[Image:Sketch vortices exp.jpg|640px|thumb|center|Figure 10: Typical mean vortices (blue streamlines) developed in the street canyon with the uniform roof height. The streamlines were obtained from later particle image velocimetry (PIV) measurements.]] | |||
<br/> | |||
[[Image:NetFLux 45.jpg|640px|thumb|center|Figure | When the wind blows at an angle of 45°, a spiral vortex is created in the street canyons ([[#figure12|Fig 12]]), which carries the pollutant up the leeward wall and down the windward wall along the street canyon ([[#figure11|Fig 11]]). But the non-uniformity of the roof height also influences the development of this pollutant transport here. The best ventilated street canyon is now the left non-uniform one, since less pollutant is transported into the canyon through the lateral opening (cf. the negative pollutant flux towards the left openings of the street canyons). In general, for the oblique wind direction all studied street canyons are better ventilated and the pollutant transport is mainly driven by the advection through the downstream lateral openings. | ||
[[Image:NetFLux 45.jpg|640px|thumb|center|Figure 11: The same as in Fig. 9 but for the oblique wind direction.]] | |||
<br/> | |||
[[Image:Sketch spiral vortex.jpg|640px|thumb|center|Figure 12: Sketch of the mean spiral vortex mean vortices (blue streamline) developed in the street canyon with the uniform roof height for the oblique wind direction.]] | |||
<br/> | |||
==Experimental data for download== | ==Experimental data for download== | ||
The following experimental data are presented in Tecplot block format. Thus, all of the values for the first variable are given in a block, then all of the values for the second variable, then all of the values for the third, and so forth. The normalised time-averaged momentum fluxes (< | The following experimental data are presented in Tecplot block format. Thus, all of the values for the first variable are given in a block, then all of the values for the second variable, then all of the values for the third, and so forth. The list of the all variables presented in the data can be found in [[EXP 1-2 Measurement Quantities and Techniques|Measurement Quantities and Techniques]]. The normalised time-averaged momentum fluxes (<math>\overline{u'w'}</math> or <math>\overline{u'v'}</math>) and the turbulent (<math>\overline{c'w'}</math> or <math>\overline{c'v'}</math>) and total pollution (<math>\overline{cw}</math> or <math>\overline{cv}</math>) fluxes are given in angle brackets (< >). The name of the data (zones in Tecplot) reflects the configuration studied, e.g. A2-L_45_z=0.6H stands for the city model A2, the left street canyon (L), the oblique wind direction (45°) and the height of the upper opening (0.6H). The data are packed according to the measured street canyon opening (TOP or LAT) and wind direction (90 degrees or 45 degrees). | ||
The data for the top openings: | The data for the top openings: | ||
Line 40: | Line 49: | ||
The data for the lateral openings: | The data for the lateral openings: | ||
[[media: | [[media:EXP_dat_LAT_90degrees.zip]] | ||
[[media:EXP_data_LAT_45degrees.zip]] | |||
= References = | |||
Nosek, Š., Kukačka, L., Jurčáková, K., Kellnerová, R., Jaňour, Z., 2017. Impact of roof height non-uniformity on pollutant transport between a street canyon and intersections. Environ. Pollut. 227, 125–138. https://doi.org/10.1016/j.envpol.2017.03.073 | |||
Nosek, Š., Kukačka, L., Kellnerová, R., Jurčáková, K., Jaňour, Z., 2016. Ventilation Processes in a Three-Dimensional Street Canyon. Boundary-Layer Meteorol. 159, 259–284. https://doi.org/10.1007/s10546-016-0132-2 | |||
<br/> | <br/> | ||
Line 50: | Line 64: | ||
|organisation=Institute of Thermomechanics of the CAS, v. v. i. | |organisation=Institute of Thermomechanics of the CAS, v. v. i. | ||
}} | }} | ||
{{ | {{EXPHeader | ||
|area=1 | |area=1 | ||
|number=2 | |number=2 |
Latest revision as of 10:24, 4 August 2023
Pollutant transport between a street canyon and a 3D urban array as a function of wind direction and roof height non-uniformity
Measurement data/results
Results
Figs 9 and 11 show the mean dimensionless total pollution fluxes through the top (at z/H = 0.6) and side openings of the studied street canyons for the vertical (90°) and oblique (45°) wind directions, respectively. The mean dimensionless total vertical pollution fluxes were calculated for the top opening as
, (1)
where c* is the instantaneous dimensionless concentration, c is the instantaneous concentration in ppm, w is the instantaneous vertical velocity component in m s-1, Uref is the reference velocity in m s-1(here the freestream velocity), H is the reference height in m (here the height of the building of uniform roofs), L is the length of the line source in m, Q is the volumetric flow of ethane from the line source in ml s-1, and the overbar denotes the time averaging. Similarly, the mean dimensionless total latera pollution fluxes were calculated for the lateral opening as
, (2)
where v is the lateral velocity component.
Fig 9a shows that in the case of the uniform roof, the pollutant is transported up the leeward wall and down the windward wall in the middle of the street canyon due to vertical recirculation (see Fig 10). Near the lateral ends of the street canyon, the pollutant is transported by horizontal recirculation, also known as corner vortex. This type of transport can also be observed at the lateral openings of the street canyon. The pollutant is removed from the street canyon through all openings (top and laterals) mainly by the turbulence, as shown by the relative contribution of turbulent pollutant fluxes to the total fluxes, which is about 70 % (Nosek et al., 2016) and can be calculated from the available data. However, in the case of the uneven roof heights, above mentioned vortices are either absent altogether, as in the case of the right uneven street canyon (Fig 9b), or they are enhanced, as in the case of the left uneven canyon (Fig 9c). In the first case, pollutant transport from the canyon through the openings is mainly driven by the advection, in the second case by the turbulence. Especially near the right lateral end (seen from downstream) of the left non-uniform canyon, there is a very strong horizontal recirculation that also retains the pollutant on the windward wall (se y = H in Fig 9c). It can also be seen from Fig 9 that both the uniform and the left non-uniform street canyon have a higher re-emission (negative total pollutant flux) of the pollutant than the right non-uniform street canyon and are therefore worse ventilated.
When the wind blows at an angle of 45°, a spiral vortex is created in the street canyons (Fig 12), which carries the pollutant up the leeward wall and down the windward wall along the street canyon (Fig 11). But the non-uniformity of the roof height also influences the development of this pollutant transport here. The best ventilated street canyon is now the left non-uniform one, since less pollutant is transported into the canyon through the lateral opening (cf. the negative pollutant flux towards the left openings of the street canyons). In general, for the oblique wind direction all studied street canyons are better ventilated and the pollutant transport is mainly driven by the advection through the downstream lateral openings.
Experimental data for download
The following experimental data are presented in Tecplot block format. Thus, all of the values for the first variable are given in a block, then all of the values for the second variable, then all of the values for the third, and so forth. The list of the all variables presented in the data can be found in Measurement Quantities and Techniques. The normalised time-averaged momentum fluxes ( or ) and the turbulent ( or ) and total pollution ( or ) fluxes are given in angle brackets (< >). The name of the data (zones in Tecplot) reflects the configuration studied, e.g. A2-L_45_z=0.6H stands for the city model A2, the left street canyon (L), the oblique wind direction (45°) and the height of the upper opening (0.6H). The data are packed according to the measured street canyon opening (TOP or LAT) and wind direction (90 degrees or 45 degrees).
The data for the top openings:
media:EXP_data_TOP_90degrees.zip
media:EXP_data_TOP_45degrees..zip
The data for the lateral openings:
media:EXP_dat_LAT_90degrees.zip
media:EXP_data_LAT_45degrees.zip
References
Nosek, Š., Kukačka, L., Jurčáková, K., Kellnerová, R., Jaňour, Z., 2017. Impact of roof height non-uniformity on pollutant transport between a street canyon and intersections. Environ. Pollut. 227, 125–138. https://doi.org/10.1016/j.envpol.2017.03.073
Nosek, Š., Kukačka, L., Kellnerová, R., Jurčáková, K., Jaňour, Z., 2016. Ventilation Processes in a Three-Dimensional Street Canyon. Boundary-Layer Meteorol. 159, 259–284. https://doi.org/10.1007/s10546-016-0132-2
Contributed by: Štěpán Nosek — Institute of Thermomechanics of the CAS, v. v. i.