EXP 1-2 Measurement Data and Results: Difference between revisions
Stepan.Nosek (talk | contribs) |
Stepan.Nosek (talk | contribs) |
||
Line 38: | Line 38: | ||
==Experimental data for download== | ==Experimental data for download== | ||
The following experimental data are presented in Tecplot block format. Thus, all of the values for the first variable are given in a block, then all of the values for the second variable, then all of the values for the third, and so forth. The normalised time-averaged momentum fluxes (< | The following experimental data are presented in Tecplot block format. Thus, all of the values for the first variable are given in a block, then all of the values for the second variable, then all of the values for the third, and so forth. The normalised time-averaged momentum fluxes (<math>\overline{u'w'}</math> or <math>\overline{u'v'}</math>) and the turbulent (<math>\overline{c'w'}</math> or <math>\overline{c'v'}</math>) and total pollution fluxes (<math>\overline{cw}</math> or <math>\overline{cv}</math>) are given in angle brackets (< >). The name of the data (zones in Tecplot) reflects the configuration studied, e.g. A2-L_45_z=0.6H stands for the city model A2, the left street canyon (L), the oblique wind direction (45°) and the height of the upper opening (0.6H). The data are packed according to the measured street canyon opening (TOP or LAT) and wind direction (90 degrees or 45 degrees). | ||
The data for the top openings: | The data for the top openings: |
Revision as of 14:43, 26 July 2023
Pollutant transport between a street canyon and a 3D urban array as a function of wind direction and roof height non-uniformity
Measurement data/results
Results
Figs. 9 and 11 show the mean dimensionless total pollution fluxes through the top (at z/H = 0.6) and side openings of the studied street canyons for the vertical (90°) and oblique (45°) wind directions, respectively. The mean dimensionless total vertical pollution fluxes were calculated for the top opening as
, (1)
where c* is the instantaneous dimensionless concentration, c is the instantaneous concentration in ppm, w is the instantaneous vertical velocity component in m s-1, Uref is the reference velocity in m s-1(here the freestream velocity), H is the reference height in m (here the height of the building of uniform roofs), L is the length of the line source in m, Q is the volumetric flow of ethane from the line source in ml s-1, and the overbar denotes the time averaging. Similarly, the mean dimensionless total latera pollution fluxes were calculated for the lateral opening as
, (2)
where v is the lateral velocity component.
Fig. 9a shows that in the case of the uniform roof, the pollutant is transported up the leeward wall and down the windward wall due to the vertical recirculation (see Fig. 10) in the middle of the street canyon. Near the lateral ends of the street canyon, the pollutant is transported by horizontal recirculation, also known as corner vortex (see Fig. 10). This type of transport can also be observed at the lateral openings of the street canyon. However, in the case of the uneven roof heights, these vortices are either absent altogether, as in the case of the right uneven street canyon (Fig. 9b), or they are enhanced, as in the case of the left uneven canyon (Fig. 9c). Especially near the right lateral end (seen from the downstream) of the left non-uniform canyon, there is a very strong horizontal recirculation that traps the pollutant also at the windward wall (se y = H in Fig. 9c). It can also be seen from Fig. 1 that both the uniform and left non-uniform street canyons have a higher re-emission (negative total pollutant flux) of the pollutant than the right non-uniform canyon and are therefore more poorly ventilated.
When the wind blows at a 45° angle, a spiral vortex (see Fig. 12) is created in the street canyons, carrying the pollutant up the leeward wall and down the windward wall (Fig. 11). But the non-uniformity of the roof height also influences the development of this pollutant transport here. The best ventilated street canyon is now the left non-uniform one, since less pollutant is transported into the canyon through the lateral opening (compare the negative pollutant flows for the left openings of the street canyons).
Experimental data for download
The following experimental data are presented in Tecplot block format. Thus, all of the values for the first variable are given in a block, then all of the values for the second variable, then all of the values for the third, and so forth. The normalised time-averaged momentum fluxes ( or ) and the turbulent ( or ) and total pollution fluxes ( or ) are given in angle brackets (< >). The name of the data (zones in Tecplot) reflects the configuration studied, e.g. A2-L_45_z=0.6H stands for the city model A2, the left street canyon (L), the oblique wind direction (45°) and the height of the upper opening (0.6H). The data are packed according to the measured street canyon opening (TOP or LAT) and wind direction (90 degrees or 45 degrees).
The data for the top openings:
media:EXP_data_TOP_90degrees.zip
media:EXP_data_TOP_45degrees..zip
The data for the lateral openings:
media:EXP_dat_LAT_90degrees.zip
media:EXP_data_LAT_45degrees.zip
Contributed by: Štěpán Nosek — Institute of Thermomechanics of the CAS, v. v. i.
© copyright ERCOFTAC 2024