EXP 1-4 Experimental Set Up: Difference between revisions
Line 13: | Line 13: | ||
The experimental setup can be divided into three | The experimental setup can be divided into three | ||
main units including the drop generator, the impact substrate and the | main units including the drop generator, the impact substrate and the | ||
observation system. The '''drop generator''' is based on a drop on demand method. A micropump | observation system. | ||
* The '''drop generator''' is based on a drop on demand method. A micropump | |||
transports the liquid from a tank to the cannula. The drop drips off | transports the liquid from a tank to the cannula. The drop drips off | ||
the cannula tip by gravity as soon as the critical mass is reached. The | the cannula tip by gravity as soon as the critical mass is reached. The | ||
impact velocity of the drop is varied by altering the height of the cannula | impact velocity of the drop is varied by altering the height of the cannula | ||
tip relative to the liquid film interface. The '''impact substrate''' is an | tip relative to the liquid film interface. | ||
* The '''impact substrate''' is an | |||
aluminium block with a recess of 70 mm diameter and 0.6 mm depth. | aluminium block with a recess of 70 mm diameter and 0.6 mm depth. | ||
The recess constrains the liquid so that films with a defined film thickness | The recess constrains the liquid so that films with a defined film thickness | ||
can be placed. The film thickness is measured by a chromatic line Sensor (Precitec | can be placed. The film thickness is measured by a chromatic line Sensor (Precitec | ||
CHRocodile CLS) which allows measuring the film thickness on 192 | CHRocodile CLS) which allows measuring the film thickness on 192 | ||
points aligned on a line of 1 mm length, to assure uniform film thickness. The '''observation system''' is described in ''Section Measurement Quantities and Techniques''. | points aligned on a line of 1 mm length, to assure uniform film thickness. | ||
* The '''observation system''' is described in ''Section Measurement Quantities and Techniques''. | |||
<br/> | <br/> |
Revision as of 08:16, 2 June 2023
Axisymmetric drop impact dynamics on a wall film of the same liquid
Experimental Setup
Describe briefly the test facility and the measurement procedure''
The experimental setup can be divided into three main units including the drop generator, the impact substrate and the observation system.
- The drop generator is based on a drop on demand method. A micropump
transports the liquid from a tank to the cannula. The drop drips off the cannula tip by gravity as soon as the critical mass is reached. The impact velocity of the drop is varied by altering the height of the cannula tip relative to the liquid film interface.
- The impact substrate is an
aluminium block with a recess of 70 mm diameter and 0.6 mm depth. The recess constrains the liquid so that films with a defined film thickness can be placed. The film thickness is measured by a chromatic line Sensor (Precitec CHRocodile CLS) which allows measuring the film thickness on 192 points aligned on a line of 1 mm length, to assure uniform film thickness.
- The observation system is described in Section Measurement Quantities and Techniques.
Contributed by: Bastian Stumpf, Milad Bagheri, Ilia V. Roisman, Cameron Tropea, Jeanette Hussong, Martin Wörner, Holger Marschall — Technical University of Darmstadt and Karlsruhe Institute of Technology