refinement in the region of separation and reattachment. This example shows | refinement in the region of separation and reattachment. This example shows | ||
that results of high quality (with respect to the time-averaged quantities) | that results of high quality (with respect to the time-averaged quantities) | ||
can be obtained on a moderate grid size | can be obtained on a moderate grid size — for diffuser 2 there was no | ||
significant difference to the wall-resolving LES with 42.0 Mio. cells. The | significant difference to the wall-resolving LES with 42.0 Mio. cells. The | ||
much finer resolutions applied by HSU-LES-DSM (up to 18 Mio. cells; Dynamic | much finer resolutions applied by HSU-LES-DSM (up to 18 Mio. cells; Dynamic | ||
Smagorinsky model was used | Smagorinsky model was used — DSM) and TUD-LES-DSM (the geometry was meshed | ||
with the grid consisting of up to 4 Mio. cells in total) resulted in a very | with the grid consisting of up to 4 Mio. cells in total) resulted in a very | ||
similar outcome with no noticeable improvement compared to the ITS-LES | similar outcome with no noticeable improvement compared to the ITS-LES | ||
Line 66: | Line 66: | ||
==Computational domain and boundary conditions== | ==Computational domain and boundary conditions== | ||
===Computational domain=== | |||
The computational domain follows exactly the | |||
experimentally investigated configuration. The computational domain | |||
comprises a part of the inlet duct (with length up to ''5h''), the entire | |||
diffuser section (''15h'') and the straight outflow duct (''12.5h''; the outflow | |||
boundary conditions are applied at the plane coinciding with the transition | |||
to the converging duct). Some computational groups located the outflow | |||
plane "somewhere" in the converging duct, e.g. TUD-LES adopted a solution | |||
domain with the outlet positioned well within the converging duct at length | |||
''9h'' (let us recall that its length is ''10h'' before transitioning to a pipe; | |||
see | |||
[[UFR_4-16#figure1|Fig. 1]] in the [[UFR_4-16#Abstract|Abstract]] and [[UFR_4-16_Description#figure2|Fig. 2]] | |||
in the [[UFR_4-16_Description#Description|Description]] section). | |||
===Inlet=== | |||
All computations presented, irrespective of the model applied, | |||
started with the velocity and turbulence-quantity profiles corresponding to | |||
a fully-developed duct flow. The latter profiles were the results of | |||
separate/precursor computations of the inflow duct of a certain length — | |||
mostly ''5h'' in the case of the eddy-resolving methods — using periodic | |||
inlet/outlet boundary conditions and the same model, the diffuser was | |||
consequently computed. It should be noted that the 3D streamwise-periodic | |||
channel of length ''5h'' used for the inflow generation might be too short, | |||
keeping in mind the spatial extent of the characteristic eddy structures, | |||
which is in general larger (due to the secondary currents) than in a | |||
(nominally 2D) channel flow with the spanwise homogeneity. Furthermore, | |||
Nikitin (2008) argued that an auxiliary streamwise-periodic simulation | |||
might not be suitable since it causes a spatial periodicity, which is not | |||
physical for turbulent flows. Let us recall that the solution domain in the | |||
DNS of | |||
[[UFR_4-16_References#24|Ohlsson ''et al.'' (2010)]] | |||
comprises an inflow development duct of ''63h'' | |||
length, accounting even for the transition of the initially laminar inflow. | |||
The present simplification of the numerical setup is certainly adequate for | |||
the RANS computations but is also pertinent to the hybrid LES/RANS method, | |||
since its overall aim is to improve the efficiency (lower computational | |||
costs) and applicability to complex geometries. In order to achieve the | |||
same basis for mutual comparison of the presently employed LES and HLR, | |||
both methods used the same inflow conditions, i.e. the same inflow duct | |||
length. In conclusion, the inflow originating from a separate computation | |||
of fully-developed duct flow by using periodic inlet/outlet boundary | |||
conditions is regarded as satisfactory; this is especially valid keeping in | |||
mind that the focus of the present study was found to be on the | |||
time-averaged flow field which was in reasonable agreement with the reference | |||
databases. | |||
===Wall=== | |||
No-slip conditions along the diffuser walls are to be applied | |||
"irrespective" of whether the governing equations are to be integrated to | |||
the wall itself — application of the exact boundary conditions | |||
corresponding to the viscous sublayer region — or some "bridging" by wall | |||
functions for "modelling" the near-wall region is used. The results suggest | |||
that the near-wall treatment is not of decisive importance. In this | |||
configuration the flow unsteadiness is introduced into the wall boundary | |||
layers from the core flow in accordance with the so-called "top-to-bottom" | |||
process. This fact justifies the use of the wall functions in conjunction | |||
with some models allowing a coarser grid resolution in the near-wall | |||
regions. This was confirmed in conjunction with the high Reynolds number | |||
Reynolds stress model (TUD-RSM) but also in the LES framework (ITS-LES-SM). | |||
===Outlet=== | |||
Different groups positioned the outlet plane differently; however, | |||
the outlet plane location was in all cases sufficiently far away from the | |||
"zone of interest", i.e. from the diffuser section. According to the | |||
experimental and DNS reference database the separation bubble ends well | |||
within the first half of the straight outlet duct at about ''6h'' (the length | |||
of this duct segment is ''12.5h''). Some groups located the outlet plane | |||
approximately at the end of the outlet duct (applying both zero-gradient | |||
and convective-outflow conditions) and some of them well within the | |||
converging duct. The ANSYS group extended the straight outlet part up to | |||
''45h'' and applied zero-gradient conditions (RANS computations have been | |||
performed). Keeping in mind that in the focus of the evaluation were the | |||
time-averaged mean flow and turbulence quantities one can conclude that the | |||
outlet plane location and associated outlet boundary conditions do not | |||
represent a critical issue. | |||
== Physical modelling == | == Physical modelling == | ||
The advice given here follows mainly from the ERCOFTAC workshops, but it is | |||
largely supported also by the results obtained in the ATAAC project. | |||
The comparison with the experimental data demonstrated that '''DNS and LES''' can | |||
reproduce the separated flow in the 3D-diffusers and the geometric | |||
sensitivity of the flow within experimental uncertainties. From an analysis | |||
of the data the following setup recommendations for LES can be deduced: | |||
There is no need to compute the long inlet channel, instead an inflow data | |||
generator suffices. There is also no need to compute the rear contraction, | |||
since an outflow with buffer zone worked well. Averaging statistics over | |||
approximately 100 flow-through times (formed with U<sub>b</sub> and diffuser length) | |||
is recommended, although smaller flow-through times can also lead to correct | |||
results (see TUD contribution). For LES, the type of SGS model and near- | |||
wall modeling / resolution seems less important than resolving the free | |||
shear layers and the largest coherent structures in the center of the | |||
diffuser. An economical Smagorinsky-type SGS-model in conjunction with wall- | |||
functions and a simple equidistant grid can suffice to predict the complex | |||
separated flow in the two asymmetric diffusers (see ITS Karlsruhe | |||
contribution). | |||
A conclusion on the '''hybrid LES/RANS simulations''' is that the high degree of | |||
geometric sensitivity found in the experiments can be well reproduced on a | |||
rather coarse grid. The separation regions in both slightly different | |||
diffusers spread as expected which is not natural for RANS. An exception is | |||
the DES method which delivers poor results and thus cannot be recommended | |||
for such internal flows, but note that in the ATAAC project IDDES produced | |||
fairly good results for diffuser 1. | |||
Furthermore, the hybrid methods generally deliver | |||
better agreement of the mean and r.m.s. velocities with the measurements | |||
than several LES predictions even when the latter were carried out on a | |||
much finer grid. Consequently, Hybrid LES/RANS approaches in general are a | |||
promising tool but still need further evaluation. | |||
The linear '''eddy-viscosity RANS''' models show no sensitivity to changes in the | |||
geometry of the diffuser section, and generally poor performance. | |||
The results obtained for both diffusers | |||
indicate almost identical flow topology. The reason for that must be | |||
primarily sought in the models' incapability to account for the Reynolds | |||
stress anisotropy governing the secondary currents in the inflow duct. The | |||
results obtained by the models based on the anisotropy-resolving | |||
'''RSM concept''' (both differential and algebraic) offer a much more differentiated | |||
picture of the flow field in reasonable agreement with the experimental | |||
data, but less so than LES and Hybrid methods as | |||
deviations still exist. This is a consequence of the | |||
incapability of RANS models in general (an unsteady computation brings no | |||
improvement) to account for any spectral dynamics associated with the large | |||
energetic eddies dominating the separated shear layers. | |||
== Application Uncertainties == | == Application Uncertainties == | ||
The configuration considered is confined by rigid walls and has one inlet | |||
(with prescribed inflow) and one outlet positioned sufficiently far away | |||
from the diffuser section (see discussion associated to the outlet boundary | |||
conditions, | |||
[[UFR_4-16_Best_Practice_Advice#Outlet|Section 2.3.4]]); | |||
at both planes there is an entirely positive | |||
through flow characterized by a fairly uniform velocity profile over the | |||
most of the cross-section. One can say that the present geometry represents | |||
a non-ambiguously defined flow configuration. Accordingly, there is not | |||
much room for any uncertainty with respect to the flow geometry, operating | |||
and boundary conditions. | |||
== Recommendations for Future Work == | == Recommendations for Future Work == | ||
The corner separation is a flow phenomenon of great industrial importance: | |||
it is relevant to all junction-shaped geometries in general; a prominent | |||
example is the junction between an aircraft wing and its fuselage. However, | |||
in such cases of practical relevance the Reynolds number is usually large | |||
while in the diffuser flows considered here the Reynolds number (Re=10000) | |||
is fairly low, i.e. not really industrially relevant. The case originators | |||
extended their investigation up to a Reynolds number of 30000; | |||
unfortunately only the surface pressure development along the flat bottom | |||
wall was measured ( | |||
[[UFR_4-16_References#8|Cherry ''et al.'', 2009]]). | |||
Hence, investigations at a higher, | |||
more industrially-relevant Reynolds number (even up to a Million) would be | |||
desirable. | |||
<br/> | <br/> | ||
---- | ---- |
Latest revision as of 14:40, 12 February 2017
Flow in a 3D diffuser
Confined flows
Underlying Flow Regime 4-16
Best Practice Advice
Key Physics
The flow in the present three-dimensional diffuser configurations is extremely complex, despite a simple geometry: namely a "through flow" in a duct — with the cross-section of its "central part" exhibiting a certain expansion and having one clearly defined inlet and one clearly defined outlet. The basic feature of the flow is a complex three-dimensional separation pattern being the consequence of an adverse pressure gradient imposed on the flow through a duct expansion. Two diffuser configurations characterized by slightly different expansion geometry but leading to completely different recirculation zone topology have been investigated. The differences are with respect to the separation onset and reattachment (form and position of the 3D separation/reattachment line) — multiple corner separation and corner reattachment — as well as with the shape and size (length, thickness, fraction of the cross-sectional area occupied by separation) of the recirculation pattern. An important prerequisite for a successful reproduction of the separating flow structure in the diffuser section is the correct capturing of the flow in the inlet duct characterized by intensive secondary currents — being normal to the main flow direction — induced by the Reynolds stress anisotropy.
Numerical Issues
Discretization
It is well-known that the accuracy of the spatial and temporal discretization in the LES-framework should be at least of the second-order. DNS results, which we regarded here more as a reference database, were obtained by applying a code with much higher accuracy level. All LES and LES-related simulations were carried out with second-order accurate discretization schemes. The latter simulations imply the application of Hybrid LES/RANS models. These model schemes employ a RANS model, consisting mostly of two additional (for k and ε) equations (e.g., the TUD-HLR model). For the equations governing such turbulent quantities some upwinding can be used by applying the so called "flux blending" technique without noticeable influence on the quality of the results.
Grid resolution and grid quality
It is interesting to note that virtually the best agreement with the reference experimental database was obtained by applying a relatively coarse grid (1.6 and 2.0 Mio. grid cells in total for diffuser 1 and 2 respectively) whose cells were distributed uniformly over the entire solution domain. In this LES simulation performed by the Karlsruhe group (ITS-LES-SM) the standard Smagorinsky model was applied in conjunction with wall functions for wall treatment. There was no specific refinement in the region of separation and reattachment. This example shows that results of high quality (with respect to the time-averaged quantities) can be obtained on a moderate grid size — for diffuser 2 there was no significant difference to the wall-resolving LES with 42.0 Mio. cells. The much finer resolutions applied by HSU-LES-DSM (up to 18 Mio. cells; Dynamic Smagorinsky model was used — DSM) and TUD-LES-DSM (the geometry was meshed with the grid consisting of up to 4 Mio. cells in total) resulted in a very similar outcome with no noticeable improvement compared to the ITS-LES results. The reasons for that lie in the nature of the flow in the present 3D diffuser (see the discussion in 2.3 and 2.4).
Computational domain and boundary conditions
Computational domain
The computational domain follows exactly the experimentally investigated configuration. The computational domain comprises a part of the inlet duct (with length up to 5h), the entire diffuser section (15h) and the straight outflow duct (12.5h; the outflow boundary conditions are applied at the plane coinciding with the transition to the converging duct). Some computational groups located the outflow plane "somewhere" in the converging duct, e.g. TUD-LES adopted a solution domain with the outlet positioned well within the converging duct at length 9h (let us recall that its length is 10h before transitioning to a pipe; see Fig. 1 in the Abstract and Fig. 2 in the Description section).
Inlet
All computations presented, irrespective of the model applied, started with the velocity and turbulence-quantity profiles corresponding to a fully-developed duct flow. The latter profiles were the results of separate/precursor computations of the inflow duct of a certain length — mostly 5h in the case of the eddy-resolving methods — using periodic inlet/outlet boundary conditions and the same model, the diffuser was consequently computed. It should be noted that the 3D streamwise-periodic channel of length 5h used for the inflow generation might be too short, keeping in mind the spatial extent of the characteristic eddy structures, which is in general larger (due to the secondary currents) than in a (nominally 2D) channel flow with the spanwise homogeneity. Furthermore, Nikitin (2008) argued that an auxiliary streamwise-periodic simulation might not be suitable since it causes a spatial periodicity, which is not physical for turbulent flows. Let us recall that the solution domain in the DNS of Ohlsson et al. (2010) comprises an inflow development duct of 63h length, accounting even for the transition of the initially laminar inflow. The present simplification of the numerical setup is certainly adequate for the RANS computations but is also pertinent to the hybrid LES/RANS method, since its overall aim is to improve the efficiency (lower computational costs) and applicability to complex geometries. In order to achieve the same basis for mutual comparison of the presently employed LES and HLR, both methods used the same inflow conditions, i.e. the same inflow duct length. In conclusion, the inflow originating from a separate computation of fully-developed duct flow by using periodic inlet/outlet boundary conditions is regarded as satisfactory; this is especially valid keeping in mind that the focus of the present study was found to be on the time-averaged flow field which was in reasonable agreement with the reference databases.
Wall
No-slip conditions along the diffuser walls are to be applied "irrespective" of whether the governing equations are to be integrated to the wall itself — application of the exact boundary conditions corresponding to the viscous sublayer region — or some "bridging" by wall functions for "modelling" the near-wall region is used. The results suggest that the near-wall treatment is not of decisive importance. In this configuration the flow unsteadiness is introduced into the wall boundary layers from the core flow in accordance with the so-called "top-to-bottom" process. This fact justifies the use of the wall functions in conjunction with some models allowing a coarser grid resolution in the near-wall regions. This was confirmed in conjunction with the high Reynolds number Reynolds stress model (TUD-RSM) but also in the LES framework (ITS-LES-SM).
Outlet
Different groups positioned the outlet plane differently; however, the outlet plane location was in all cases sufficiently far away from the "zone of interest", i.e. from the diffuser section. According to the experimental and DNS reference database the separation bubble ends well within the first half of the straight outlet duct at about 6h (the length of this duct segment is 12.5h). Some groups located the outlet plane approximately at the end of the outlet duct (applying both zero-gradient and convective-outflow conditions) and some of them well within the converging duct. The ANSYS group extended the straight outlet part up to 45h and applied zero-gradient conditions (RANS computations have been performed). Keeping in mind that in the focus of the evaluation were the time-averaged mean flow and turbulence quantities one can conclude that the outlet plane location and associated outlet boundary conditions do not represent a critical issue.
Physical modelling
The advice given here follows mainly from the ERCOFTAC workshops, but it is largely supported also by the results obtained in the ATAAC project.
The comparison with the experimental data demonstrated that DNS and LES can reproduce the separated flow in the 3D-diffusers and the geometric sensitivity of the flow within experimental uncertainties. From an analysis of the data the following setup recommendations for LES can be deduced: There is no need to compute the long inlet channel, instead an inflow data generator suffices. There is also no need to compute the rear contraction, since an outflow with buffer zone worked well. Averaging statistics over approximately 100 flow-through times (formed with Ub and diffuser length) is recommended, although smaller flow-through times can also lead to correct results (see TUD contribution). For LES, the type of SGS model and near- wall modeling / resolution seems less important than resolving the free shear layers and the largest coherent structures in the center of the diffuser. An economical Smagorinsky-type SGS-model in conjunction with wall- functions and a simple equidistant grid can suffice to predict the complex separated flow in the two asymmetric diffusers (see ITS Karlsruhe contribution).
A conclusion on the hybrid LES/RANS simulations is that the high degree of geometric sensitivity found in the experiments can be well reproduced on a rather coarse grid. The separation regions in both slightly different diffusers spread as expected which is not natural for RANS. An exception is the DES method which delivers poor results and thus cannot be recommended for such internal flows, but note that in the ATAAC project IDDES produced fairly good results for diffuser 1. Furthermore, the hybrid methods generally deliver better agreement of the mean and r.m.s. velocities with the measurements than several LES predictions even when the latter were carried out on a much finer grid. Consequently, Hybrid LES/RANS approaches in general are a promising tool but still need further evaluation.
The linear eddy-viscosity RANS models show no sensitivity to changes in the geometry of the diffuser section, and generally poor performance. The results obtained for both diffusers indicate almost identical flow topology. The reason for that must be primarily sought in the models' incapability to account for the Reynolds stress anisotropy governing the secondary currents in the inflow duct. The results obtained by the models based on the anisotropy-resolving RSM concept (both differential and algebraic) offer a much more differentiated picture of the flow field in reasonable agreement with the experimental data, but less so than LES and Hybrid methods as deviations still exist. This is a consequence of the incapability of RANS models in general (an unsteady computation brings no improvement) to account for any spectral dynamics associated with the large energetic eddies dominating the separated shear layers.
Application Uncertainties
The configuration considered is confined by rigid walls and has one inlet (with prescribed inflow) and one outlet positioned sufficiently far away from the diffuser section (see discussion associated to the outlet boundary conditions, Section 2.3.4); at both planes there is an entirely positive through flow characterized by a fairly uniform velocity profile over the most of the cross-section. One can say that the present geometry represents a non-ambiguously defined flow configuration. Accordingly, there is not much room for any uncertainty with respect to the flow geometry, operating and boundary conditions.
Recommendations for Future Work
The corner separation is a flow phenomenon of great industrial importance:
it is relevant to all junction-shaped geometries in general; a prominent
example is the junction between an aircraft wing and its fuselage. However,
in such cases of practical relevance the Reynolds number is usually large
while in the diffuser flows considered here the Reynolds number (Re=10000)
is fairly low, i.e. not really industrially relevant. The case originators
extended their investigation up to a Reynolds number of 30000;
unfortunately only the surface pressure development along the flat bottom
wall was measured (
Cherry et al., 2009).
Hence, investigations at a higher,
more industrially-relevant Reynolds number (even up to a Million) would be
desirable.
Contributed by: Suad Jakirlić, Gisa John-Puthenveettil — Technische Universität Darmstadt