UFR 4-16 Evaluation: Difference between revisions

From KBwiki
Jump to navigation Jump to search
Line 50: Line 50:
quantitative information about the U? velocity can  be  extracted  from  the
quantitative information about the U? velocity can  be  extracted  from  the
friction factor evolution, Fig. 14 in the chapter "Test case studied").
friction factor evolution, Fig. 14 in the chapter "Test case studied").
===Adverse Pressure Gradient (APG) effects===
The boundary layer separation is  the  direct  consequence  of  the  Adverse
Pressure Gradient imposed on the duct flow by  expanding  the  cross-section
area. The following figures should give the potential practitioners  insight
into the  topology  and  magnitude  of  the  pressure  recovery  within  the
diffuser  section.  Fig.  24-upper  displays  the  non-dimensional  pressure
gradient  p+=?  dp/dx  /  (?U3?)  used  traditionally  to  characterize  the
intensity of the pressure increase in a boundary layers  subjected  to  APG.
Accordingly, the displayed results enable a direct comparison with some  APG
boundary layer experiments. E.g., the range of  p+  between  0.01-0.025  was
documented in the Nagano et al. (1993) experiments, indicating a much  lower
level than in the present diffuser.  Although  the  results  presented  were
extracted from the LES and Hybrid LES/RANS simulations their quality  is  of
a fairly high level,  keeping  in  mind  good  agreement  of  the  near-wall
velocity field (see the section "Cross-Comparison of CFD  calculations  with
experimental results"), skin-friction (Fig. 14 in  the  chapter  "Test  case
studied")  and  surface  pressure  (Fig.  24-lower)  development  with  the
reference experimental and DNS results.





Revision as of 18:23, 1 August 2012

Flow in a 3D diffuser

Front Page

Description

Test Case Studies

Evaluation

Best Practice Advice

References

Confined flows

Underlying Flow Regime 4-16

Evaluation of the results

Both 3D diffuser configurations have served as test cases of the 13th and 14th ERCOFTAC SIG15 Workshops on refined turbulence modelling, Steiner et al. (2009) and Jakirlic et al. (2010b). In addition to different RANS models, the LES and LES-related methods (different seamless and zonal hybrid LES/RANS - HLR - models; DES - Detached Eddy Simulation) were comparatively assessed (visit www.ercoftac.org; under SIG15); the comparative analysis of selected results is presented in the section "Cross- Comparison of CFD calculations with experimental results" of the present contribution. Before starting with the latter, some key physical characteristics illustrated appropriately are discussed as follows.

Physical issues/characteristics of the flow in a 3D diffuser

Here an overview of the most important flow features posing a special challenge to the turbulence modeling is given. Their correct capturing is of decisive importance with respect to the quality of the final results. In order to illustrate these phenomena the experimental and DNS results are used along with some results obtained by LES, hybrid LES/RANS and RANS methods by the groups participating at the SIG15 workshop.

Developed ("equilibrium") flow in the inflow duct / secondary currents

Fig. 20 depicts the linear plot of the axial velocity component across the central plane (z/B=0.5) of the inflow duct at x/h=-2 obtained experimentally indicating a symmetric profile. The inflow conditions correspond clearly to those typical for a fully-developed, equilibrium flow. This is provided by a long inflow duct whose length corresponds to 62.9 channel heights. Fig. 21 shows the semi-log plot of the axial velocity component across the central plane (z/B=0.5) of the inflow duct at x/h=-2. The velocity profile shape obtained by DNS follows closely the logarithmic law, despite a certain departure from it. This departure, expressed in terms of a slight underprediction of the coefficient B in the log-law ([pic] with B=5.2), can also be regarded as a consequence of the back- influence of the adverse pressure gradient evoked by the flow expansion. The pressure coefficient evolution, displayed in Fig. 24, reveals a related pressure increase already in the inflow duct ([pic]). The LES and HLR results (Jakirlic et al., 2010a) exhibit a certain overprediction of the velocity in the logarithmic region. This seems to indicate that the grid may not have been fine enough. On the other hand, the corresponding underprediction of the friction velocity U?, serving here for the normalization - [pic], contributed also to such an outcome (the quantitative information about the U? velocity can be extracted from the friction factor evolution, Fig. 14 in the chapter "Test case studied").

Adverse Pressure Gradient (APG) effects

The boundary layer separation is the direct consequence of the Adverse Pressure Gradient imposed on the duct flow by expanding the cross-section area. The following figures should give the potential practitioners insight into the topology and magnitude of the pressure recovery within the diffuser section. Fig. 24-upper displays the non-dimensional pressure gradient p+=? dp/dx / (?U3?) used traditionally to characterize the intensity of the pressure increase in a boundary layers subjected to APG. Accordingly, the displayed results enable a direct comparison with some APG boundary layer experiments. E.g., the range of p+ between 0.01-0.025 was documented in the Nagano et al. (1993) experiments, indicating a much lower level than in the present diffuser. Although the results presented were extracted from the LES and Hybrid LES/RANS simulations their quality is of a fairly high level, keeping in mind good agreement of the near-wall velocity field (see the section "Cross-Comparison of CFD calculations with experimental results"), skin-friction (Fig. 14 in the chapter "Test case studied") and surface pressure (Fig. 24-lower) development with the reference experimental and DNS results.





Contributed by: Suad Jakirlić, Gisa John-Puthenveettil — Technische Universität Darmstadt

Front Page

Description

Test Case Studies

Evaluation

Best Practice Advice

References


© copyright ERCOFTAC 2024