UFR 4-08 Evaluation

From KBwiki
Revision as of 19:28, 29 August 2009 by Niek.verhoeven (talk | contribs)
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

Front Page

Description

Test Case Studies

Evaluation

Best Practice Advice

References




Orifice/deflector flow

Underlying Flow Regime 4-08               © copyright ERCOFTAC 2004


Evaluation

Comparison of CFD calculations with Experiments

A comparison of the numerical results with the experiments was conducted for both cases A and B. The mean velocities were predicted reasonably well, however, a small over-prediction of the axial velocity in the region of the vena contracta was observed (Fig. 6). In the shear layer at x/H = 2 the turbulent kinetic energy was considerably under-predicted. Further downstream an over-prediction of the maximum k-value was found (Fig. 6). The above conclusions can be also made for case A, however, the agreement with the measurements was slightly better, especially for the turbulent kinetic energy. The calculated normalized wall friction coefficient for this case also agreed very well with the measurements (Fig. 7)

 

U4-08d32 files image024.jpg

Fig. 6 Comparison of computed and measured profiles of the mean velocities and the turbulent kinetic energy for case B with Re = 22,000 using 248 x 56 grids

U4-08d32 files image026.jpg

Fig. 7 Comparison of the computed and measured normalized wall friction coefficient along the pipe, starting at the orifice for case A and Re = 22,000

© copyright ERCOFTAC 2004



Contributors: Martin Sommerfeld - Martin-Luther-Universitat Halle-Wittenberg