Test Case AC2-07: Difference between revisions

From KBwiki
Jump to navigation Jump to search
m (Dave.Ellacott moved page Gold:Test Case AC2-07 to Test Case AC2-07 over redirect)
 
(15 intermediate revisions by 3 users not shown)
Line 1: Line 1:
{{AC|front=AC 2-07|description=Description_AC2-07|testdata=Test Case_AC2-07|cfdsimulations=CFD Simulations_AC2-07|evaluation=Evaluation_AC2-07|qualityreview=Quality Review_AC2-07|bestpractice=Best Practice Advice_AC2-07|relatedUFRs=Related UFRs_AC2-07}}
='''Confined double annular jet'''=
='''Confined double annular jet'''=


Line 182: Line 184:
Axial and radial components of the velocity in the laboratory coordinate system are provided by the 2D LDA system. The data are processed to provide at each position, mean axial and radial velocities, axial and radial turbulence intensities and the cross-moment providing the stress, estimated using a coincidence window of duration 0.05 s. The mean tangential velocity is theoretically 0 and is not recorded. The tangential turbulence intensity is not recorded but can be assumed to be equal to the radial turbulence intensity, due to local isotropy relative to the axis of symmetry.
Axial and radial components of the velocity in the laboratory coordinate system are provided by the 2D LDA system. The data are processed to provide at each position, mean axial and radial velocities, axial and radial turbulence intensities and the cross-moment providing the stress, estimated using a coincidence window of duration 0.05 s. The mean tangential velocity is theoretically 0 and is not recorded. The tangential turbulence intensity is not recorded but can be assumed to be equal to the radial turbulence intensity, due to local isotropy relative to the axis of symmetry.


Tables in the preceding section have given the GNDP and PDP for this experiment.
Tables in the preceding section have given the
[[DOAPs#GNDPs:_Governing_Non-Dimensional_Parameters|GNDP]]
and [[DOAPs#PDPs:_Problem_Definition_Parameters|PDP]] for this experiment.


In the following, the velocities are normalized by , second moments by and length scales by the radius =78 mm.
In the following, the velocities are normalized by U<sub>2</sub>,
second moments by U<sub>2</sub><sup>2</sup> and length scales by the
radius&nbsp;r<sub>2</sub>&nbsp;=&nbsp;78 mm.


Measurements correspond to a grid with corners (0,-1.3), (3.1,-1.3), (3.1, 1.3), (0, 1.3). A dense experimental grid has been chosen: each traverse corresponds to sections along the y direction, with between 201 and 401 measuring positions. 36 traverse positions between x=0 and x=3.1 have been chosen, corresponding to an experimental grid of 5,500 points (see Figure 4).
Measurements correspond to a grid with corners (0,-1.3), (3.1,-1.3), (3.1, 1.3), (0, 1.3). A dense experimental grid has been chosen: each traverse corresponds to sections along the y direction, with between 201 and 401 measuring positions. 36 traverse positions between x=0 and x=3.1 have been chosen, corresponding to an experimental grid of 5,500 points (see Figure 4).
Line 220: Line 226:


{| border="1" align="center" width="450"
{| border="1" align="center" width="450"
|+ align="bottom" | <b>Table 6. Average error for the five measured quantities
|+ align="bottom" | <b>Table 6. Average error for the five measured quantities</b>
! align="center" | Quantity
! align="center" | Quantity
| align="center" | U
| align="center" | U
Line 253: Line 259:
! align="center" width="100"| Distance to nozzle (mm)
! align="center" width="100"| Distance to nozzle (mm)
! align="center" width="100"| Normalised distance to nozzle
! align="center" width="100"| Normalised distance to nozzle
! align="center" width="100"| Data file
|-
|-
| align="center" | 1 ||align="center"| 0 ||align="center"| 0
|align="center"|1 ||align="center"| 0 ||align="center"| 0 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp000.dat}} exp000.dat]</span>
|-
|-
|align="center"|2 ||align="center"| 5 ||align="center"| 0.06
|align="center"|2 ||align="center"| 5 ||align="center"| 0.06 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp006.dat}} exp006.dat]</span>
|-
|-
|align="center"|3 ||align="center"| 10 ||align="center"| 0.14
|align="center"|3 ||align="center"| 10 ||align="center"| 0.14 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp014.dat}} exp014.dat]</span>
|}
 
<!--
|-
|-
|4 || 15 || 0.19
|align="center"|4 ||align="center"| 15 ||align="center"| 0.19 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp019.dat}} exp019.dat]</span>
|-
|-
|5 || 20 || 0.26
|align="center"|5 ||align="center"| 20 ||align="center"| 0.26 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp026.dat}} exp026.dat]</span>
|-
|-
|6 || 25 || 0.32
|align="center"|6 ||align="center"| 25 ||align="center"| 0.32 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp032.dat}} exp032.dat]</span>
|-
|-
|7 || 30 || 0.38
|align="center"|7 ||align="center"| 30 ||align="center"| 0.38 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp038.dat}} exp038.dat]</span>
|-
|-
|8 || 35 || 0.45
|align="center"|8 ||align="center"| 35 ||align="center"| 0.45 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp045.dat}} exp045.dat]</span>
|-
|-
|9 || 40 || 0.51
|align="center"|9 ||align="center"| 40 ||align="center"| 0.51 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp051.dat}} exp051.dat]</span>
|-
|-
|10 || 45 || 0.58
|align="center"|10 ||align="center"| 45 ||align="center"| 0.58 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp058.dat}} exp058.dat]</span>
|-
|-
|11 || 50 || 0.64
|align="center"|11 ||align="center"| 50 ||align="center"| 0.64 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp064.dat}} exp064.dat]</span>
|-
|-
|12 || 55 || 0.70
|align="center"|12 ||align="center"| 55 ||align="center"| 0.70 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp070.dat}} exp070.dat]</span>
|-
|-
|13 || 60 || 0.77
|align="center"|13 ||align="center"| 60 ||align="center"| 0.77 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp077.dat}} exp077.dat]</span>
|-
|-
|14 || 65 ||  0.83
|align="center"|14 ||align="center"| 65 ||align="center"|  0.83 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp083.dat}} exp083.dat]</span>
|-
|-
|15 || 70 || 0.90
|align="center"|15 ||align="center"| 70 ||align="center"| 0.90 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp090.dat}} exp090.dat]</span>
|-
|-
|16 || 75 || 0.96
|align="center"|16 ||align="center"| 75 ||align="center"| 0.96 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp096.dat}} exp096.dat]</span>
|-
|-
|17 || 80 || 1.02
|align="center"|17 ||align="center"| 80 ||align="center"| 1.02 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp102.dat}} exp102.dat]</span>
|-
|-
|18 || 85 || 1.09
|align="center"|18 ||align="center"| 85 ||align="center"| 1.09 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp109.dat}} exp109.dat]</span>
|-
|-
|19 || 90 || 1.15
|align="center"|19 ||align="center"| 90 ||align="center"| 1.15 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp115.dat}} exp115.dat]</span>
|-
|-
|20 || 95 || 1.22
|align="center"|20 ||align="center"| 95 ||align="center"| 1.22 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp122.dat}} exp122.dat]</span>
|-
|-
|21 || 100 || 1.28
|align="center"|21 ||align="center"| 100 ||align="center"| 1.28 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp128.dat}} exp128.dat]</span>
|-
|-
|22 || 110 || 1.41
|align="center"|22 ||align="center"| 110 ||align="center"| 1.41 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp141.dat}} exp141.dat]</span>
|-
|-
|23 || 120 || 1.54
|align="center"|23 ||align="center"| 120 ||align="center"| 1.54 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp154.dat}} exp154.dat]</span>
|-
|-
|24 || 130 || 1.67
|align="center"|24 ||align="center"| 130 ||align="center"| 1.67 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp167.dat}} exp167.dat]</span>
|-
|-
|25 || 140 || 1.79
|align="center"|25 ||align="center"| 140 ||align="center"| 1.79 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp179.dat}} exp179.dat]</span>
|-
|-
|26 || 150 || 1.92
|align="center"|26 ||align="center"| 150 ||align="center"| 1.92 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp192.dat}} exp192.dat]</span>
|-
|-
|27 || 160 || 2.05
|align="center"|27 ||align="center"| 160 ||align="center"| 2.05 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp205.dat}} exp205.dat]</span>
|-
|-
|28 || 170 || 2.18
|align="center"|28 ||align="center"| 170 ||align="center"| 2.18 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp218.dat}} exp218.dat]</span>
|-
|-
|29 || 180 || 2.31
|align="center"|29 ||align="center"| 180 ||align="center"| 2.31 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp231.dat}} exp231.dat]</span>
|-
|-
|30 || 190 || 2.44
|align="center"|30 ||align="center"| 190 ||align="center"| 2.44 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp244.dat}} exp244.dat]</span>
|-
|-
|31 || 200 || 2.56
|align="center"|31 ||align="center"| 200 ||align="center"| 2.56 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp256.dat}} exp256.dat]</span>
|-
|-
|32 || 210 || 2.69
|align="center"|32 ||align="center"| 210 ||align="center"| 2.69 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp269.dat}} exp269.dat]</span>
|-
|-
|33 || 220 || 2.82
|align="center"|33 ||align="center"| 220 ||align="center"| 2.82 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp282.dat}} exp282.dat]</span>
|-
|-
|34 || 230 || 2.95
|align="center"|34 ||align="center"| 230 ||align="center"| 2.95 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp295.dat}} exp295.dat]</span>
|-
|-
|35 || 240 || 3.08
|align="center"|35 ||align="center"| 240 ||align="center"| 3.08 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp308.dat}} exp308.dat]</span>
|-
|-
|36 || 250 || 3.20
|align="center"|36 ||align="center"| 250 ||align="center"| 3.20 ||align="center"| <span class="plainlinks">[{{filepath:AC2-07_exp320.dat}} exp320.dat]</span>
|}
|}
Table 7. Position of each traverse file
-->


=='''Test Case EXP-2'''==
=='''Test Case EXP-2'''==
Line 339: Line 339:




{|border="1" cell padding="20" cell spacing="3"
{|border="1" align="center"
!Componemt (subscript used)!!Inner diameter, d mm!!Outer diameter, D mm!!Length, L mm
|+ align="bottom"|<b>Table 8. Dimensions of the model for water tunnel.</b>
!align="center"|Component (subscript used)
!align="center"|Inner diameter, d mm
!align="center"|Outer diameter, D mm
!align="center"|Length, L mm
|-
|-
|Primary Nozzle (p) || 21.0 || 25.0 || 5.0
|align="center"|Primary Nozzle (<sub>p</sub>)  
|align="center"| 21.0 ||align="center"| 25.0 ||align="center"| 5.0
|-
|-
|Primary Duct (pd) || 21.0 || 29.0 || 195.0
|align="center"|Primary Duct (<sub>pd</sub>)  
|align="center"| 21.0 ||align="center"| 29.0 ||align="center"| 195.0
|-
|-
|Secondary Nozzle (s) || 35.0 || 39.0 || 5.0
|align="center"|Secondary Nozzle (<sub>s</sub>)
|align="center"| 35.0 ||align="center"| 39.0 ||align="center"| 5.0
|-
|-
|Secondary Duct (sd) || 35.0 || 44.0 || 195.0
|align="center"|Secondary Duct (<sub>sd</sub>)
|align="center"| 35.0 ||align="center"| 44.0 ||align="center"| 195.0
|-
|-
|Cold Chamber (c) || 91.0 || 91.2 || 290.0
|align="center"|Cold Chamber (<sub>c</sub>)
|align="center"| 91.0 ||align="center"| 91.2 ||align="center"| 290.0
|}
|}




Table 8. Dimensions of the model for water tunnel.


[[Image:Image153.gif]]
[[Image:Image153.gif]]
Line 444: Line 452:
Site Design and Implementation: [[Atkins]] and [[UniS]]
Site Design and Implementation: [[Atkins]] and [[UniS]]
        Top              Next
{{AC|front=AC 2-07|description=Description_AC2-07|testdata=Test Case_AC2-07|cfdsimulations=CFD Simulations_AC2-07|evaluation=Evaluation_AC2-07|qualityreview=Quality Review_AC2-07|bestpractice=Best Practice Advice_AC2-07|relatedUFRs=Related UFRs_AC2-07}}

Latest revision as of 15:34, 11 February 2017

Front Page

Description

Test Data

CFD Simulations

Evaluation

Best Practice Advice

Confined double annular jet

Application Challenge 2-07 © copyright ERCOFTAC 2004


Overview of Tests

An overview of the experimental test cases is provided here. The values of the PDP and GNDP in the 2 experiments are first provided. Then experiments are described, and the DOAP given. The measured quantities are then presented in tables.

Table 3. The different parameters for the two test cases
Parameters Symbol Experimental Database #1 Experimental Database #2
Geometric Parameters r1 50.5mm 12.5mm
r2 78mm 19.5mm
dr 8mm 2mm
rc 191mm 45.5mm
Fluid Dynamic Data Fluid Air Water
U1 6.3m/s
U2 6.1m/s
Ue 0.09m/s
PDP 0.97
1.55 1.56
45.5 41.4
GNDP Re 3x104 3.5x103
Ct 0.24 0.24


Experiment of database 1

Measurements procedure. Measurements for Experimental databases #1 and #2 are taken using a 2D LDA system. The power source is an Argon Ion Laser with rated output of 4 watts, of which 1.7 watt is emitted in the green color (514.5 nm) and 1.3 watt is emitted in the blue color (488.0 nm).

The LDA system used in experiment 1 is based on fiber optics, with back scatter method and has processors based on spectrum analysis of the back scattered signals. The crossing of the beams generates an ellipsoidal probe volume, of radius approximately 0.12 mm and length 0.9 mm. The measurement point can be chosen and moved using a 3D traverse system. The green and blue beams belong to 2 planes whose intersection is called the LDA probe axis. The measurements are operated using data acquisition software.

Data processing. The data acquisition software includes some automatic filters in order to retain the record of only those considered valid among the detected particles. Raw valid data are recorded for each position: velocity, transit time and arrival time. After the acquisition, data can be processed.

Variables measured. For each position, all the valid data have been stored. Several statistical quantities have also been estimated for each position, given in the following Table. The cross-moment is estimated taking into account only the pair of data belonging to a coincidence window of duration 50 ms. This condition reduces the number of valid points taken into account to estimate this statistical quantity. For experimental database #1 recorded using LDV measurements at different positions, the statistical averages are computed taking successive particles at the same position. For experimental database #2 recorded using PIV, the statistical averages correspond to a ensemble average over several successive images.

Experiment of database 2

Measurements procedure. The 4W Argon Ion laser used in experiment 1 was used in this experiment also. The measurement system employed here is a two-dimensional two-component (2D2C) system utilizing a single camera. The PIV system was designed and system integration was done at VUB. The software used was developed by DLR, Gottingen, Germany. This set of experiments were conducted under the following specific conditions:

• 4W Argon ion laser as the light source.

• Acousto-optical modulator (AOM) controlled by a sequencer to generate frame-straddled pulses from continuous wave laser.

• Mirrors and cylindrical lens to generate the light sheet of nominal thickness 2 mm.

• High-resolution full-frame interline transfer CCD camera for image recording. The frame rate of the camera is 12 s1 and has 1026x1296 pixels CCD array. A frame grabber transfers the frames to a hard disc.

• Air filled glass spheres of 9 mm mean diameter and with specific gravity 1.04 as seeding.

• The scale of the image was 191 pixels/cm.

• The pulse duration was 600 ms and the pulse separation was 2500 ms in this experiment.


Boundary/Initial conditions. A carefully controlled amount of water was allowed to flow through the model burner in the test-rig shown in Figure 5. De-mineralized water at room temperature flows through the model at 4.09x10-5 m3/s producing a mean exit velocity Ue = 0.09 m/s in this particular set of experiments.

Data processing. The data acquisition and processing software used at VUB was for spatial cross correlation velocimetry. The accuracy of measurement depends on the hardware and set-up conditions. Interrogation area of 32x32 and 16x16 shift in pixel level was employed for data processing. The maximum displacement was of the order 6 pixels giving good correlation peak. The peak locking effect was also found to be negligible.


Table 4. DOAP for the 2 test cases.
Point # in Fig.2 Description Position in Database #1 Position (axial distance from the face) in Database #2
a Central stagnation point (0, 1.00) 1.308
b Centre of the central toroidal vortex (0.52, 0.44)
c Stagnation line associated with the toroidal vortex (0.32, 0.75) 0.331
d Centre of the first small toroidal vortex (0.20, 0.71)
e Centre of the second small toroidal vortex (0.21, 0.81)



Table 5. Recorded data for the two test cases
Quantity Description Experimental Database #1 Experimental Database #2
Mean axial velocity Statistical computation over 3000 to 16000 particles. Mean and RMS are calculated from 271 vector fields.

Shear stress at each grid point can be computed if required.

Mean radial velocity
Axial turbulence intensity
radial turbulence intensity
Reynolds shear stress component

Test Case EXP-1

Description of Experiment

Axial and radial components of the velocity in the laboratory coordinate system are provided by the 2D LDA system. The data are processed to provide at each position, mean axial and radial velocities, axial and radial turbulence intensities and the cross-moment providing the stress, estimated using a coincidence window of duration 0.05 s. The mean tangential velocity is theoretically 0 and is not recorded. The tangential turbulence intensity is not recorded but can be assumed to be equal to the radial turbulence intensity, due to local isotropy relative to the axis of symmetry.

Tables in the preceding section have given the GNDP and PDP for this experiment.

In the following, the velocities are normalized by U2, second moments by U22 and length scales by the radius r2 = 78 mm.

Measurements correspond to a grid with corners (0,-1.3), (3.1,-1.3), (3.1, 1.3), (0, 1.3). A dense experimental grid has been chosen: each traverse corresponds to sections along the y direction, with between 201 and 401 measuring positions. 36 traverse positions between x=0 and x=3.1 have been chosen, corresponding to an experimental grid of 5,500 points (see Figure 4).


Image130.jpg



Figure 4: Experimental grid chosen for the measurements.

The original data set is first interpolated on a finer and more regular (along Oz axis) grid, keeping all the original traverse positions, and interpolating raw data along each traverse, on a grid of size 0.5-mm in the z direction. This produces a smoother behavior of the particle traces. This new data set is symmetrized: for a given value of x, where the average values at position (x, 0,z) and (x, 0, -z) is set as the values at these two points. For all experimental values, this gives a perfectly axisymmetric field. An error field is also recorded: this represents the axisymmetric errors, and corresponds to the raw data minus the averaged data. It gives a map showing the percentage of error in axisymmetry.


Boundary Data

The inflow is a fully developed annular flow. The combustion chamber is cylindrical and 4 tubes evacuate the flow far from the nozzle region, so that it is expected that the outflow conditions have no influence on the measurements.


Measurement Errors

The sources leading to the error in the mean quantities and non-axisymmetry are discussed and an estimation of these errors is given in this section. These errors can come from several independent origins:

(a). Errors in the mean velocity of the inlet flow: This corresponds to errors of the rotation speed of the compressor. This can be controlled using the incremental shaft encoder recording the rotation speed of the compressor with a precision of 0.1 rpm. For these measurements rotation speed of 2000 rpm is used. Due to fluctuations in the electrical power supply, or to mechanical defaults, the compressor rotation speed presents some unavoidable fluctuations. Using a very sensitive potentiometer, this rotation speed was maintained inside the interval (1990, 2010), which corresponds to an error of .5%.

(b). Errors in the estimation of the instantaneous velocities by the LDA system: This velocity is proportional to the Doppler frequency shift, which is estimated through a Fourier transform. Since this law is linear and the proportionality factor is fixed, the LDA apparatus does not need any calibration. The burst spectrum analyzer used to process the Doppler signal received from the probe volume has high resolution. This provides at the output a very low error, depending on the record length. In the present experiment, the record length for the first beam (axial velocity) is 16 and 64 for the second (radial velocity), giving (according to the manufacturer’s specifications) errors of 0.025 % and 0.006 % for axial and radial velocity respectively. This is an infinitesimal source of error compared to the other sources.

(c). Statistical error in the mean values: Since the in-flow conditions are stationary with good precision, it can be stated that when taking N measurements, the mean of these N values converges toward the true average, when the measurements are taken during a time larger than the correlation time. With a Reynolds number of about 3., the flow is fully turbulent, and presents an energy cascade, which introduces correlations. These correlations are characterized by the largest eddy in the system, given by the dimension of the outer jet, of diameter 0.16 m. With a mean velocity in this region of about 4 m/s, the largest time scale of correlation at a given position is of the order of 40 ms. Depending on the zone of the flow considered, the detection of several thousands particles took between 10 s and 2 minutes, which is much larger than the correlation time. This confirms that the mean of N values should converge toward the true mean value.

The convergence of the statistics depends on the number of events that are chosen. A direct test can be applied, indicating that to reach an error of less than 2%, N=3,000 is sufficient for axial velocity and stress, whereas N=800 is sufficient for radial velocity. For better accuracy in the measured quantities, at each grid point several thousands data (between 3,000 and 16,000 depending on the location) have been recorded. This will provide statistical errors that are below, or of the same order of magnitude as the geometry errors.

(d). Geometrical errors in building the burner leading to a non-axisymmetry: When all other sources of errors are minimized, a superposition of different traverse provides a direct estimate of the geometry error. With careful construction this error is kept to a minimum, since, in order to provide comparisons between measurements and CFD codes, very good axisymmetry of the measurements is needed. This error has been checked for different traverse positions close to the nozzle exit. The excellent superposition (within 1%) of the measured quantities from different angular positions shows that at the exit the axisymmetry is of high quality. For axial and radial velocity, turbulent kinetic energy and stress, there is globally a very good superposition: the average error (relative to ) is below 2% for mean values and for second moments (relative to the maximum kinetic energy, km=0.18); the average error in the quantities U, V, τuu, τνν and τ for the nozzle region are given in Table 6.


Table 6. Average error for the five measured quantities
Quantity U V τuu τνν τ
Average Error (%) 1.6 1.1 1.3 1.3 0.7


Measured Data

The data base is organized as follows: it is given as 36 text files, one for each traverse (unequally spaced between x=0 and x=3.2, see Table 2), containing experimental data corresponding to each of the 401 data points along the radial direction. Each file provides the 5 basic quantities and their axisymmetry errors, i.e. the following values: z, U(z), V(z), τuu(z), τnu;ν(z), τ(z), δU(z), δV(z), δτuu(z), δτνν(z), δτ(z) for 401 values of z equally spaced between –1.28 and 1.28.

The data are given as ASCII files. The overall size is 2 MB.


Table 7 Position of each traverse file
Traverse # Distance to nozzle (mm) Normalised distance to nozzle Data file
1 0 0 exp000.dat
2 5 0.06 exp006.dat
3 10 0.14 exp014.dat
4 15 0.19 exp019.dat
5 20 0.26 exp026.dat
6 25 0.32 exp032.dat
7 30 0.38 exp038.dat
8 35 0.45 exp045.dat
9 40 0.51 exp051.dat
10 45 0.58 exp058.dat
11 50 0.64 exp064.dat
12 55 0.70 exp070.dat
13 60 0.77 exp077.dat
14 65 0.83 exp083.dat
15 70 0.90 exp090.dat
16 75 0.96 exp096.dat
17 80 1.02 exp102.dat
18 85 1.09 exp109.dat
19 90 1.15 exp115.dat
20 95 1.22 exp122.dat
21 100 1.28 exp128.dat
22 110 1.41 exp141.dat
23 120 1.54 exp154.dat
24 130 1.67 exp167.dat
25 140 1.79 exp179.dat
26 150 1.92 exp192.dat
27 160 2.05 exp205.dat
28 170 2.18 exp218.dat
29 180 2.31 exp231.dat
30 190 2.44 exp244.dat
31 200 2.56 exp256.dat
32 210 2.69 exp269.dat
33 220 2.82 exp282.dat
34 230 2.95 exp295.dat
35 240 3.08 exp308.dat
36 250 3.20 exp320.dat

Test Case EXP-2

The test bed used for these measurements is shown in Figure 5. The model of the burner used is shown in Figure 6. Table 8 gives a summary of the flow passages and the area investigated in this experiment.


Table 8. Dimensions of the model for water tunnel.
Component (subscript used) Inner diameter, d mm Outer diameter, D mm Length, L mm
Primary Nozzle (p) 21.0 25.0 5.0
Primary Duct (pd) 21.0 29.0 195.0
Secondary Nozzle (s) 35.0 39.0 5.0
Secondary Duct (sd) 35.0 44.0 195.0
Cold Chamber (c) 91.0 91.2 290.0


Image153.gif


Figure 5: Schematic view of the test bed for experiment 2


Figure 7 shows a sample of an instantaneous vector field. The particle traces represent streamlines in this figure. The highly 3-D nature of the field is demonstrated in this figure.

Figure 8 shows the mean vector field of all the 270 instantaneous velocity fields. It is seen that the 3-D nature seen before has been eliminated from the result. The particle traces represent streamlines in this figure also. The axisymmetry is also quite high in this figure. For comparison, the positions are determined from this figure.


Image154.gif


Figure 6: Schematic view of model used in experiment 2

Image181.jpg


Figure 7: An instanteous velocity yield.

Image155.gif


Figure 8: The average velocity yield calculated from all the 270 vector fields.

Description of Experiment

The experiment provides the two components of the instantaneous vector field in the meridional plane in the nozzle region in an 80x63 uniform grid. Each of the 271 files also contains the complete processing history.

GNDP and PDP are given in the tables of the preceding section.

The grid and the velocities are given in cm and cm/s, respectively in these files. The coordinate system has its origin at lower left corner with the first quadrant vector directions. The comparison with origin at axis should be attempted after shifting the origin. The average velocity field should be used for this purpose.

Boundary Data

The velocity profile of the inlet flow to the combustion chamber is fully developed flow between two parallel plates at Re = 180.

Alternatively, computation could be started from the inlet to the ducts (geometry given in Table 8) with constant total pressure.

The flow has an unrestricted discharge at the combustion chamber exit. The volumetric flow rate is 4.09x10-5 m3/s.

Measurement Errors

There are 4 major sources of measurement errors in the instantaneous vector fields associated with PIV data acquisition and processing these are listed below.

The additional uncertainties in the average velocity and RMS velocity fields appear when these are calculated from all the 271 vector fields. These uncertainties are:

Mean quantities 3%

RMS and Reynolds stresses 2%

• Flow variation

The variation of flow through the model was smaller than 0.1% during the measurement.

• Spatial resolution

The interrogation window covered a square area of 1.68 mm on each direction in the physical plane and the window is shifted by 0.88 mm for each interrogation. Thus, the averaging region is a volume close to 5.6 mm3. Therefore, close to the nozzle exit, in the shear layers, the velocity profile is not reliable.

• Temporal resolution

The pulse duration was 600ms and the pulse separation was 2500 ms. The “instantaneous” value obtained is actually the value averaged over 2500 ms. Therefore, all fluctuations at frequencies higher than 400 Hz are averaged out.

• Outliers removal

Each vector field contains 5040 interrogated vectors. On the average 50 outliers were detected and interpolated. Therefore, about 1% of the vectors are interpolated.

• Uncertainty in displacement

The uncertainty in displacement determination is given as 0.02 pixels. Therefore, the uncertainty in velocity is less than 0.5%.

Measured Data

271 instantaneous vector fields each containing 5040 vectors and their vorticity, shear strain and normal strain fields in a uniform grid are offered. Each field is given in a NetCDF file with 80x63 vectors for velocity and 78x61 scalars for the rest. In addition, an average vector field file and an RMS file computed from the instantaneous field are present.

The files could be converted to text files. Text files written in four columns; x, z, Vx and Vz, could also be deposited to the database depending on demand.

© copyright ERCOFTAC 2004


Contributors: Charles Hirsch; Francois G. Schmitt - Vrije Universiteit Brussel

Site Design and Implementation: Atkins and UniS


Front Page

Description

Test Data

CFD Simulations

Evaluation

Best Practice Advice