Data Formats and Submission for ACs, UFRs and EXPs: Difference between revisions

From KBwiki
Jump to navigation Jump to search
No edit summary
(Replaces 'member' with 'contributor')
(5 intermediate revisions by 2 users not shown)
Line 1: Line 1:
= QNET-CFD Knowledge Base Data Formats and Submission =
= Knowledge Base Wiki Data Formats and Submission for ACs and UFRs=
==Purpose of Document ==
==Purpose of Document ==
This document provides guidance to members who are submitting data to be included in the QNET-CFD Knowledge Base. It is important that members read the content carefully before preparing and submitting their data files. This document sets out the required format for each type of data file, what metadata is required and the folder structures that should be used when submitting data. The total storage space available per Application Challenge will be subject to a limit of 500 MB.
This document provides guidance to contributors who are submitting data to be included in the Knowledge Base Wiki. It is important that contributors read the content carefully before preparing and submitting their data files. This document sets out the required format for each type of data file, what metadata is required and the folder structures that should be used when submitting data. The total storage space available per Application Challenge will be subject to a limit of 500 MB.
==Data Structure and Format==
==Data Structure and Format==
===Directory Structure===
===Directory Structure===
All the data files associated with an Application Challenge should be submitted as a single appropriately named folder[1], containing three subfolders named ‘X’, ‘C’ and ‘I’. All experimental data must be contained within the directory named ‘X’, all CFD data in the directory named ‘C’ and all images in a directory named ‘I’. Any further directory structure within these three subfolders and the data filenames, are at the discretion of the Member providing the data. The total storage space available per Application Challenge will be subject to a limit of 500 MB.
All the data files associated with an Application Challenge should be submitted as a single appropriately named folder[1], containing three subfolders named ‘X’, ‘C’ and ‘I’. All experimental data must be contained within the directory named ‘X’, all CFD data in the directory named ‘C’ and all images in a directory named ‘I’. Any further directory structure within these three subfolders and the data filenames, are at the discretion of the contributor providing the data. The total storage space available per Application Challenge will be subject to a limit of 500 MB.
===File Type Segregation===
===File Type Segregation===
Data stored in the Knowledge Base are separated into the following three classes:  
Data stored in the Knowledge Base are separated into the following three classes:  
Line 23: Line 23:


The metadata associated with a large data file must be stored in a separate ASCII file residing in the same directory as the large data file and having the same name except with a “.met” extension. This metadata file shall contain all the Problem Definition Parameters (PDPs) common to the entire data file and also information about the data columns presented as prescribed in Appendix A.
The metadata associated with a large data file must be stored in a separate ASCII file residing in the same directory as the large data file and having the same name except with a “.met” extension. This metadata file shall contain all the Problem Definition Parameters (PDPs) common to the entire data file and also information about the data columns presented as prescribed in Appendix A.
=== DNS CFD Data files ===
The data files for the DNS entries maybe several hundreds of GB's and so a separate large file hosting system has been developed that will store these files on the AWS S3 service. Please see [[High_fidelity_data_storage|DNS Data Storage]] for further guidance.


== Data Submission, Storage and Retrieval ==
== Data Submission, Storage and Retrieval ==
=== Data Submission Methods ===
=== Data Submission Methods ===
* FTP (for data sets of the order of tens of MB or less).  '''This is done by special arrangement with the QNET Editorial team.'''
* FTP (for data sets of the order of tens of MB or less).  '''This is done by special arrangement with the KB Wiki Editorial team. Please email admin@cado-ercoftac.org'''


* CD ROM, DVD or DLT (for data sets of the order of hundreds of MB)
* CD ROM, DVD or DLT (for data sets of the order of hundreds of MB)


Inform the KB curator of ftp access via email. Contact the QNET editorial team for delivery details if the data is being sent by post.
* AWS S3 (for data sets of the order of hundreds of GB)
 
Inform the KB Wiki Team of ftp access via email. Contact the KB Wiki Team team for delivery details if the data is being sent by post.


===  Data Storage ===
===  Data Storage ===
Line 60: Line 65:


where <nTA> = 1 to 45.is the Thematic Area number and N is the AC number, e.g. 4-01 refers to the first AC in TA4 “Wind environment around an airport terminal building” by WS Atkins.
where <nTA> = 1 to 45.is the Thematic Area number and N is the AC number, e.g. 4-01 refers to the first AC in TA4 “Wind environment around an airport terminal building” by WS Atkins.
Note that the Application Challenge number corresponds to the QNET-CFD member number (i.e. 41 for University of Surrey, 2 for WS Atkins). If any member is to submit more than one AC, then the convention is to use the member number followed by a,b,c,….(e.g. 8a, 8b).


* The variables listed for each column of data using the machine-readable format, for example:
* The variables listed for each column of data using the machine-readable format, for example:


<pre>
<pre>


Line 87: Line 89:
The value assigned to %Column1Name must be a string containing no unprintable characters (apart from spaces) and if possible it should conform to the CGNS convention for data name identifiers. For details of CGNS conventions, see [http://www.grc.nasa.gov/www/cgns/sids/dataname.html]  
The value assigned to %Column1Name must be a string containing no unprintable characters (apart from spaces) and if possible it should conform to the CGNS convention for data name identifiers. For details of CGNS conventions, see [http://www.grc.nasa.gov/www/cgns/sids/dataname.html]  


The value assigned to %Column1Units is left to the discretion of the members but once again it must be a string containing no unprintable characters except spaces.
The value assigned to %Column1Units is left to the discretion of the contributor, but once again it must be a string containing no unprintable characters except spaces.


The value assigned to %Column1Type must be either “Integer”, “Real” or “String”
The value assigned to %Column1Type must be either “Integer”, “Real” or “String”
Line 244: Line 246:




 
The name of the data folder will be based on the reference identifier given to the contributor(s) by the KB Wiki Team.  Each contributor will be assigned a unique id based on their name.
The name of the data folder will be based on the reference identifier given to the contributor(s) by the QNET Editorial team.  Each contributor will be assigned a unique id based on their name.

Revision as of 11:12, 17 January 2021

Knowledge Base Wiki Data Formats and Submission for ACs and UFRs

Purpose of Document

This document provides guidance to contributors who are submitting data to be included in the Knowledge Base Wiki. It is important that contributors read the content carefully before preparing and submitting their data files. This document sets out the required format for each type of data file, what metadata is required and the folder structures that should be used when submitting data. The total storage space available per Application Challenge will be subject to a limit of 500 MB.

Data Structure and Format

Directory Structure

All the data files associated with an Application Challenge should be submitted as a single appropriately named folder[1], containing three subfolders named ‘X’, ‘C’ and ‘I’. All experimental data must be contained within the directory named ‘X’, all CFD data in the directory named ‘C’ and all images in a directory named ‘I’. Any further directory structure within these three subfolders and the data filenames, are at the discretion of the contributor providing the data. The total storage space available per Application Challenge will be subject to a limit of 500 MB.

File Type Segregation

Data stored in the Knowledge Base are separated into the following three classes:

  • Graphical Data Files (independent of size)
  • Small Data Files - Experimental or CFD data files that are less than about 2Mb when stored in ASCII format.
  • Large Data Files - Experimental or CFD data files that would be more than about 2Mb if stored in ASCII format.

In the following sections the file formats required for each of these three classes will be discussed and must be adhered to when submitting documents.

Graphical Data Files (independent of size)

Static images must have extensions of either “.gif” or “.jpg” or “.png” depending on which format is the most suitable for a given image type.

Files containing movie clips should have extensions of either “.mpg” or “.avi” or “.mov”.

Small Data files

‘Small’ data files have a size smaller than approximately 2Mb when stored in ASCII format. These data files must be in ASCII format and should have the extension .dat. They should also contain their own metadata at the top of the file as indicated in Appendix A below. This metadata header states the Problem Definition Parameters (PDPs) common to the entire data file and also information about the data columns presented. Following the metadata header the file should only contain columns of tab separated data with the rows being separated by CR/LF (Carriage Return/Line Feed) characters. The data type in each column must be either Integer, Real or String, as declared in the metadata. No metadata or any other type of comments should appear after the “%End of Metadata” line. An example of a small data file is provided in Appendix B.

Large Data files

‘Large’ data files are larger than 2Mb when stored in ASCII format. These can be structured in any format convenient to the subscriber. However, instructions for reading and interpreting the data must be provided in the metadata file. The specific information required is a definition of the file format, usually a well-known keyword, and an optional version number.

The metadata associated with a large data file must be stored in a separate ASCII file residing in the same directory as the large data file and having the same name except with a “.met” extension. This metadata file shall contain all the Problem Definition Parameters (PDPs) common to the entire data file and also information about the data columns presented as prescribed in Appendix A.

DNS CFD Data files

The data files for the DNS entries maybe several hundreds of GB's and so a separate large file hosting system has been developed that will store these files on the AWS S3 service. Please see DNS Data Storage for further guidance.

Data Submission, Storage and Retrieval

Data Submission Methods

  • FTP (for data sets of the order of tens of MB or less). This is done by special arrangement with the KB Wiki Editorial team. Please email admin@cado-ercoftac.org
  • CD ROM, DVD or DLT (for data sets of the order of hundreds of MB)
  • AWS S3 (for data sets of the order of hundreds of GB)

Inform the KB Wiki Team of ftp access via email. Contact the KB Wiki Team team for delivery details if the data is being sent by post.

Data Storage

The data will be stored in the format in which they were submitted.

Data Retrieval

Data files will be downloadable in the format in which they were submitted.

Before downloading the larger data files, users are requested to inspect the associated metadata of the file to be sure they have the expected content. In this way, the load on the server can be managed. A future development will enable portions of large data files to be retrieved and this option is currently being investigated.

Appendix A: Metadata Required

The metadata (data about data) which must be provide for each data file shall contain the following information in ASCII format:

  • Values of all the defining parameters specified for the Application Challenge which do not explicitly appear as a separate column in the data file. These rows should be prefixed by a # symbol.
  • The Thematic Area, using machine-readable format:
%TA = <n>

where <n> = 1, 2, 3, 4, 5 or 6.


  • The Application Challenge number, using machine readable format:
%AC = <nTA-N>

where <nTA> = 1 to 45.is the Thematic Area number and N is the AC number, e.g. 4-01 refers to the first AC in TA4 “Wind environment around an airport terminal building” by WS Atkins.

  • The variables listed for each column of data using the machine-readable format, for example:

%Column1Name = VelocityX

%Column1Units = m/s

%Column1Type = Real 

%Column2Name = Sensor Location on Wing

%Column2Units = mm

%Column2Type = String 

etc. for each column in the file


The value assigned to %Column1Name must be a string containing no unprintable characters (apart from spaces) and if possible it should conform to the CGNS convention for data name identifiers. For details of CGNS conventions, see [1]

The value assigned to %Column1Units is left to the discretion of the contributor, but once again it must be a string containing no unprintable characters except spaces.

The value assigned to %Column1Type must be either “Integer”, “Real” or “String”

Entries are case-sensitive and should follow the exact specification given.

For large data files that are not based on column data it is recommended that a format identifier and if possible a format version identifier be provided. These take the format shown in the following template:


%Format = <MY_FORMAT>

%FormatVersion = <MY_FORMAT_VERSION>

  • The metadata must end with the following machine readable-command:
%End Of Metadata

Appendix B: Example of Small data ASCII files

############################################################

#

# TA1 External Aerodynamics AC41 Oscillating Delta Wing

#

# File contains ANOVA-results of the Pressure Coefficients -Cp

# of the Kulite Pressure Transducers

#

# Free stream Velocity : 40 ms-1 (± 0.06 %)

# Reynolds number      : 3.1E6

# Mach number          : 0.12

# Mode                 : Pitch

# Angle of Attack      : 0.0 deg

# Oscillation Amplitude           : 6 deg

############################################################

%TA = 1

%AC = 1-4110

%Column1Name = value for red. Frequ. = 0.28

%Column1Units = rad/s

%Column1Type = Real 

%Column2Name = value for red. Frequ. = 0.56

%Column2Units = rad/s

%Column2Type = Real

%Column3Name = confidence interval for 95% probability

%Column3Units = Non-dimensional

%Column3Type = Real

%Column4Name = Side Of Wing

%Column4Units = Location

%Column4Type = String

%Column5Name = x/ci

%Column5Units = ratio

%Column5Type = Real

%Column6Name = eta

%Column6Units = degrees

%Column6Type = Real

%End Of Metadata

0.0931     0.0907     0.0080     Right      0.3        0.700

0.2934     0.3035     0.0010     Right      0.3        0.700

-4.4748    -9.6125    0.0600     Right      0.3        0.700

0.0798     0.0869     0.0010     Right      0.3        0.700

-17.5862   -37.9607   0.3240     Right      0.3        0.700

0.0230     0.0274     0.0000     Right      0.3        0.700

-25.8954   -50.8786   1.6030     Right      0.3        0.700

0.1060     0.1104     0.0020     Left       0.3        0.700

0.2874     0.2975     0.0010     Left       0.3        0.700

-4.5508    -9.6137    0.1160     Left       0.3        0.700

0.0779     0.0848     0.0010     Left       0.3        0.700

-18.4120   -39.0618   0.6240     Left       0.3        0.700

0.0219     0.0265    0.0010     Left       0.3        0.700

-28.0049   -54.2960   2.2470     Left       0.3        0.700

0.1006     0.1015    0.0020     Left       0.3        0.850

0.3287     0.3403     0.0010     Left       0.3        0.850

-1.4226    -3.4499    0.0370     Left       0.3        0.850

0.0818     0.0866     0.0010     Left       0.3        0.850

-0.8961    -4.9886    0.3980     Left       0.3        0.850

0.0118     0.0166     0.0000     Left       0.3        0.850

22.3086    32.6002    2.5760     Left       0.3        0.850

0.0992     0.0834     0.0050     Left       0.6        0.700

0.1712     0.1730     0.0010     Left       0.6        0.700

0.4754     1.7458     0.1840     Left       0.6        0.700

0.0437     0.0487     0.0010     Left       0.6        0.700

-34.5128   -66.4447   1.0530     Left       0.6        0.700

0.0400     0.0444     0.0010     Left       0.6        0.700

-43.8689   -84.7527   1.1160     Left       0.6        0.700


--------------------------------------------------------------------------------



The name of the data folder will be based on the reference identifier given to the contributor(s) by the KB Wiki Team. Each contributor will be assigned a unique id based on their name.