Jump to navigation Jump to search
mNo edit summary
No edit summary
Line 1: Line 1:
{{AC|front=AC 6-12|description=AC 6-12 Description|testdata=AC 6-12 Test Data|cfdsimulations=AC 6-12 CFD Simulations|evaluation=AC 6-12 Evaluation|qualityreview=AC 6-12 Quality Review|bestpractice=AC 6-12 Best Practice Advice|relatedACs=AC 6-12 Related ACs}}
{{AC|front=AC 6-12|description=AC 6-12 Description|testdata=AC 6-12 Test Data|cfdsimulations=AC 6-12 CFD Simulations|evaluation=AC 6-12 Evaluation|qualityreview=AC 6-12 Quality Review|bestpractice=AC 6-12 Best Practice Advice|relatedUFRs=AC 6-12 Related ACs}}


==Application Area 6: Turbomachinery Internal Flows==
==Application Area 6: Turbomachinery Internal Flows==
Line 24: Line 24:
''Contributors: Jaromir Prihoda; Karel Kozel - Czech Academy of Sciences''
''Contributors: Jaromir Prihoda; Karel Kozel - Czech Academy of Sciences''


{{AC|front=AC 6-12|description=AC 6-12 Description|testdata=AC 6-12 Test Data|cfdsimulations=AC 6-12 CFD Simulations|evaluation=AC 6-12 Evaluation|qualityreview=AC 6-12 Quality Review|bestpractice=AC 6-12 Best Practice Advice|relatedACs=AC 6-12 Related ACs}}
{{AC|front=AC 6-12|description=AC 6-12 Description|testdata=AC 6-12 Test Data|cfdsimulations=AC 6-12 CFD Simulations|evaluation=AC 6-12 Evaluation|qualityreview=AC 6-12 Quality Review|bestpractice=AC 6-12 Best Practice Advice|relatedUFRs=AC 6-12 Related ACs}}


[[Category:Application Challenge]]
[[Category:Application Challenge]]

Revision as of 15:33, 13 March 2009

Front Page

Description

Test Data

CFD Simulations

Evaluation

Best Practice Advice

Application Area 6: Turbomachinery Internal Flows

Application Challenge AC6-12

Abstract

The results of experimental investigation of fluid flow in blade cascades at transonic flow regimes are invaluable for improvements of turbine designs and for verification of CFD codes. Higher efficiency and operational reliability of turbines and compressors can be reach by coupling of experimental and numerical modelling of flow in cascades.

The transonic flow in a steam turbine rotor cascade was selected for the application challenge. The investigation of the SE 1050 blade cascade includes experimental test data based on interferometric pictures of fluid flow and numerical simulation using models of inviscid flow (home-made software) and of viscous flow (FLUENT code).

As the testcase, the measurement for the inlet angle b1 = 70.7 deg and the exit isentropic Mach numbers 1.198 was chosen. The basic series of measurements was made for the inlet angle b1 = 70.7 deg (incidence i = 0 deg) with the exit isentropic Mach numbers changed in the range (0.489, 1.387). Some additional experiments were carried out for extreme values of incidence covering the range from very small loading to overloading conditions.

The blade cascades belong to most important elements in turbomachinery and their design is crucial for the efficiency and operational reliability of turbines and compressors. This is valid especially for turbines of large output. The chosen profile cascade called SE 1050 was designed for the last stage of a SKODA steam turbine with the blade length 1085 mm and a nominal speed of 3000 rpm. The SE 1050 profile is a section of a rotor blade at the distance 320 mm from the root. The cascade operated in the transonic regime was chosen as the testcase suitable for testing of numerical methods and verification of experimental methods as well.

Following parameters are used as crucial for the appraisal of CFD calculations:

  • isolines of the Mach number and/or density in the flow field of the blade cascade
  • pressure and Mach number distribution on the profile surface
  • energy losses
  • exit flow angle.



Contributors: Jaromir Prihoda; Karel Kozel - Czech Academy of Sciences


Front Page

Description

Test Data

CFD Simulations

Evaluation

Best Practice Advice