Jump to navigation Jump to search
No edit summary
No edit summary
Line 20: Line 20:
{{UFR|front=UFR 4-08|description=UFR 4-08 Description|references=UFR 4-08 References|testcase=UFR 4-08 Test Case|evaluation=UFR 4-08 Evaluation|qualityreview=UFR 4-08 Quality Review|bestpractice=UFR 4-08 Best Practice Advice|relatedACs=UFR 4-08 Related ACs}}
{{UFR|front=UFR 4-08|description=UFR 4-08 Description|references=UFR 4-08 References|testcase=UFR 4-08 Test Case|evaluation=UFR 4-08 Evaluation|qualityreview=UFR 4-08 Quality Review|bestpractice=UFR 4-08 Best Practice Advice|relatedACs=UFR 4-08 Related ACs}}


[[Category:Confined Flow]]
[[Category:Confined Flow|Orifice/deflector flow]]
{{#set:hasContributorOrg=Martin-Luther-Universitat Halle-Wittenberg}}
{{#set:hasContributorOrg=Martin-Luther-Universitat Halle-Wittenberg}}
{{#set:hasContributorPerson=Martin Sommerfeld}}
{{#set:hasContributorPerson=Martin Sommerfeld}}
{{#set:hasQualityAccessLevel=SilverStar}}
{{#set:hasQualityAccessLevel=SilverStar}}

Revision as of 10:17, 19 October 2011

Front Page

Description

Test Case Studies

Evaluation

Best Practice Advice

References



Confined Flows

Underlying Flow Regime 4-08

Abstract

The flow through a sharp-edged orifice plate mounted concentric into a pipe of constant cross-section induces a flow contraction and a separation downstream of the orifice plate. The narrowest cross-section of the flow is however not located in the orifice itself, but some distance downstream (Figure 1). The region of the narrowest cross-section is often called “vena contracta”. Further downstream of this location the flow expands again up to the pipe cross-section. Naturally, such a flow configuration is associated with a considerable pressure loss, since a great deal of kinetic energy is dissipated within the recirculation region. Therefore, such an orifice plate is often used as a flow meter mounted into a pipe (Hayward 1979). For such an application normally a special design of the orifice hole is used and the pressure tapings should be mounted at a certain distance with respect to the orifice location (Figure 2).

Figure 1. Illustration of the flow structure through a pipe with a sharp-edge orifice plate.
Figure 2. Different designs of the orifice plates used for flow meters.



Contributors: Martin Sommerfeld - Martin-Luther-Universitat Halle-Wittenberg