Best Practice Advice AC1-01

From KBwiki
Revision as of 14:42, 11 February 2017 by Dave.Ellacott (talk | contribs) (Dave.Ellacott moved page Silver:Best Practice Advice AC1-01 to Best Practice Advice AC1-01 over redirect)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

Front Page

Description

Test Data

CFD Simulations

Evaluation

Best Practice Advice

Aero-acoustic cavity

Application Challenge 1-01 © copyright ERCOFTAC 2004


Best Practice Advice for the AC

Key Fluid Physics


D34 image002.gif


Description of Application Challenge


D34 image004.gif


(Figure dimensions in inches)


• M219 Transonic Cavity

• M∞ = 0.85

• L/D (length/depth ratio) = 5


• W/D (width/depth ratio) = 1

• ReL = 6.84x106



DOAPs

On 10 points along cavity ceiling;

• RMS pressures

• Power Spectral Density (PSD) or Sound Pressure Level (SPL)


Flow Physics

• Sharp edge separation

• Cavity flow recirculation

• Shear layer oscillation. The DOAPs are driven by the shear layer oscillation, therefore it is important to resolve this feature well.

• Large eddy structures

• Coherent (vortex shedding) and broadband (turbulent) structures


Underlying Flow Regimes

• Cavity Flow

• 2D Unsteady Shear Layer

Neither of these are in the Knowledge Base.


Application Uncertainties

• Upstream turbulence level

• Boundary layer ahead of cavity leading edge – not known whether the boundary layer is tripped or not.


Computational Domain and Boundary Conditions

Computational Domain

• Upstream domain starts at rig sharp leading edge, downstream one cavity length behind cavity trailing edge.

• Side domains one cavity width away from side edge.


Boundary Conditions

• M=0.85, T=305.06K on upstream boundary

• Side boundaries, top boundary and downstream boundary, constant pressure = 62059.14Pa

• No slip conditions on cavity walls, with hybrid low-Re / wall-function


Discretisation and Grid Resolution

• Second-order special discretisation (MARS) on momentum

• Hexahedral orthogonal meshes with successive 2x2 refinement into the shear layer and walls are necessary. Mesh dependency analysis shows low sensitivity to refiments greater than 40000 cells in the 2D plane.

• Better than 1st order temporal discretsation


Physical Modelling

• Transient

• Compressible ideal gas

• Low-Reynolds number k-epsilon (linear and non-liners) turbulence models


Recommendations for Future Work

• Extension to 3D

• LES-based turbulence modeling

• Full second-order central differencing special discretisation in the LES flow regions

Both these recommendations have been followed in later studies reported by the Application Challenge Author – see additional reference section below [1,3].


Additional References

[1] Mendonca, F., Allen, R., de Charentenay, J. and Kirkham, D., “CFD Prediction of narrowband and broadband cavity acoustics at M=0.85”, AIAA-2003-3303, 9th AIAA/CEAS Aeroacoustics Conference and Exhibit, Hilton Head, South Carolina, USA, May 2003.

[2] Allen, R., and Mendonça, F., “DES Predictions on the M219 cavity at M=0.85”, Colloquium EUROMECH 449, Chamonix, France, 7-8th December 2003

[3] Allen, R., and Mendonça, F., “DES Validations of Cavity Acoustics over the subsonic to Supersonic Range”, AIAA-2004-2862, 10th AIAA/CEAS Aeroacoustics Conference and Exhibit, Manchester, UK, May 2004

© copyright ERCOFTAC 2004




Contributors: Fred Mendonca; Richard Allen - Computational Dynamics Ltd